Multizentrische Studie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Franscesco Solimene und 22 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Electrophysiology and Arrhythmology, Clinica Montevergine, Mercogliano, Italy. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation, Algorithms. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The combination of highly localized impedance (LI) and contact force (CF) may improve tissue characterization and lesion prediction during radiofrequency (RF) pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). OBJECTIVE: We report the outcomes of our acute and long-term clinical evaluation of CF-LI-guided PVI in consecutive AF ablation cases from an international multicenter clinical setting. METHODS: Three hundred twenty-four consecutive patients from 20 European centers undergoing RF catheter ablation with the Stablepoint™ catheter were enrolled in the CHARISMA registry. Of these, 275 had a minimum follow-up of 1 year and were included in the primary analysis. RESULTS: The mean procedure duration was 115 ± 47 min, and the mean fluoroscopy time was 9.9 ± 6 min. At the end of the procedures, all PVs had been successfully isolated in all study patients. Minor complications were reported in 12 patients (4.4%). At 1 year, 36 (13.1%) patients had had an AF recurrence, and freedom from antiarrhythmic drugs and AF recurrence was achieved in 228 (82.9%) patients. The recurrence rate was higher in patients with persistent AF (21/116, 18.1%) than in those with paroxysmal AF (15/159, 9.4%; p = 0.0459). On multivariate logistic analysis adjusted for baseline confounders, only time > 6 months from first diagnosis of AF to ablation (HR = 2.93, 95%CI 1.03 to 8.36, p = 0.0459) was independently associated with recurrences. CONCLUSION: An ablation strategy for PVI guided by CF-LI technology proved safe and effective and resulted in a low recurrence rate of AF over 1-year follow-up, irrespective of the underlying AF type. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice. (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiac Electrophysiology and Arrhythmology, Clinica Montevergine, Mercogliano, Italy.
- Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy.
- Laboratorio Di Elettrofisiologia, Infermi Hospital, 29, Rivoli, Italy. ruggero.maggio@gmail.com.
- IRCCS Ospedale Galeazzi - Sant'Ambrogio, Milan, Italy.
- Centre Cardiologique du Nord, Saint-Denis, France.
- Boston Scientific, Milan, Italy.
Zitieren
APA
Solimene, F., Maggio, R., De Sanctis, V., Escande, W., Malacrida, M., Stabile, G., Zakine, C., Champ-Rigot, L., Anselmino, M., Ferraro, A., Mantica, M., Zucchelli, G., Dell'Era, G., Mascia, G., Ricci Maga, R., Pandozi, C., Rossi, P., Scaglione, M., Zingarini, G., …, & Lepillier, A. (2024). Contact-force local impedance algorithm to guide effective pulmonary vein isolation in AF patients: 1-year outcome from an international multicenter clinical setting. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01849-0
Vancouver
Solimene F, Maggio R, De Sanctis V, Escande W, Malacrida M, Stabile G, et al. Contact-force local impedance algorithm to guide effective pulmonary vein isolation in AF patients: 1-year outcome from an international multicenter clinical setting. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01849-0
BibTeX
@article{Solimene2024,
author = {Solimene, Franscesco and Maggio, Ruggero and De Sanctis, Valerio and Escande, William and Malacrida, Maurizio and Stabile, Giuseppe and Zakine, Cyril and Champ-Rigot, Laure and Anselmino, Matteo and Ferraro, Anna and Mantica, Massimo and Zucchelli, Giulio and Dell'Era, Gabriele and Mascia, Giuseppe and Ricci Maga, Renata and Pandozi, Claudio and Rossi, Pietro and Scaglione, Marco and Zingarini, Gianluca and Garnier, Fabien and Loricchio, Maria Luisa and Pelargonio, Gemma and Lepillier, Antoine},
title = {Contact-force local impedance algorithm to guide effective pulmonary vein isolation in AF patients: 1-year outcome from an international multicenter clinical setting},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
doi = {10.1007/s10840-024-01849-0}
}
EUVIMED