Comparison between cryotherapy and radiofrequency energy sources for parahisian accessory pathway percutaneous ablation
Journal of Interventional Cardiac Electrophysiology · 2024
DOI: 10.1007/s10840-024-01841-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Italo Bruno Dos Santos Sousa und 9 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Arrhythmia Unit, Heart Institute (InCor), University of Sao Paulo Medical School, Sao Paulo, SP, Brazil. ibss_bruno@hotmail.com. Hauptthemen laut MEDLINE: Accessory Atrioventricular Bundle, Cryosurgery, Catheter Ablation. Die Arbeit nennt 37 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Catheter ablation of parahisian accessory pathways (PHAP) are challenging due to their proximity to the normal conduction system. Retrospective studies suggest that cryoablation has a better safety profile but a higher recurrence rate when compared to radiofrequency ablation (RFCA). The objective of this study was to compare the results of parahisian AP ablation performed by electrophysiologists with experience in both technologies. METHODS: Prospective single-center, non-blinded and 1:1 model was used. Patients included had parahisian AP confirmed by an electrophysiological study and referred for radiofrequency or cryotherapy ablation according to current guidelines, under fluoroscopic guidance. No electroanatomic mapping was used. RESULTS: A total of 30 patients (mean age of 25±9.4 years; 90% male) were enrolled between Oct/2018 to Feb/2020. Acute success rate between RFCA and CRYO were similar (93% vs. 87%, p = 0.54). A nonsignificant reduction in short-term recurrence rate for RFCA (14% vs. 30%, p = 0.3) and mechanical trauma (6% vs. 20%; p = 0.28) was observed. Long-term recurrence rate and event-free survival time were similar in both groups after 1-year follow-up (p = 0.286). No persistent complete AV block or conduction disturbance was also observed. CONCLUSION: Considering the limitation of a small sample size and the lack of use of electroanatomic mapping for RFCA, the efficacy and safety profile of parahisian AP ablation with RFCA was not different from CRYO, when performed by experienced electrophysiologists. No cases of permanent complete AV block were reported with either energy modalities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Arrhythmia Unit, Heart Institute (InCor), University of Sao Paulo Medical School, Sao Paulo, SP, Brazil. ibss_bruno@hotmail.com.
- Cardiac Arrhythmia Unit, Heart Institute (InCor), University of Sao Paulo Medical School, Sao Paulo, SP, Brazil.
Zitieren
APA
Dos Santos Sousa, I. B., Chokr, M. O., Melo, S. L., Pisani, C. F., Hardy, C. A., de Moura, L. G., Sacilotto, L., Wu, T. C., Darrieux, F. C. C., & Scanavacca, M. I. (2024). Comparison between cryotherapy and radiofrequency energy sources for parahisian accessory pathway percutaneous ablation. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01841-8
Vancouver
Dos Santos Sousa IB, Chokr MO, Melo SL, Pisani CF, Hardy CA, de Moura LG, et al. Comparison between cryotherapy and radiofrequency energy sources for parahisian accessory pathway percutaneous ablation. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01841-8
BibTeX
@article{DosSantosSousa2024,
author = {Dos Santos Sousa, Italo Bruno and Chokr, Muhieddine Omar and Melo, Sissy Lara and Pisani, Cristiano Faria and Hardy, Carina Abigail and de Moura, Lucas Goyanna and Sacilotto, Luciana and Wu, Tan Chen and Darrieux, Francisco Carlos Costa and Scanavacca, Mauricio Ibrahim},
title = {Comparison between cryotherapy and radiofrequency energy sources for parahisian accessory pathway percutaneous ablation},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
doi = {10.1007/s10840-024-01841-8}
}
EUVIMED