Catheter ablation of atrial fibrillation with nonfluoroscopic catheter visualization—a prospective randomized comparison
Journal of Interventional Cardiac Electrophysiology · 2019-01 · 54 (1) · 35-42
DOI: 10.1007/s10840-018-0446-8 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 18.09.2018. Verfasst von Sascha Rolf und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, DRK Kliniken Berlin Westend, Spandauer Damm 130, 14050, Berlin, Germany. sascha.rolf@web.de. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: The application of a novel platform for nonfluoroscopic catheter sensor tracking within pre-recorded x-ray loops in the context of catheter ablation of atrial fibrillation (AF) demonstrated significant potential for reduction of fluoroscopy. We sought to provide the first prospective randomized comparison of fluoroscopy needs, procedure times, and complications in AF catheter ablation with or without additional use of nonfluoroscopic catheter visualization (NFCV). METHODS: Patients with AF were randomized into two groups before scheduled radiofrequency ablation: (1) using established mapping systems and fluoroscopy as needed (CONV group) or (2) with additional NFCV (NFCV group). All procedures were performed in the same lab using the same ablation catheter tip technology and the same mapping and ablation strategies. Primary endpoints were radiation time and dose. Secondary endpoints were procedural parameters, complications, and long-term success. RESULTS: A total of 80 patients (48 male patients, mean age 60 years, 46 patients with paroxysmal AF) were randomized into the two groups. Clinical parameters between both groups were similar. NFCV use reduced mean fluoroscopy time (1.9 vs. 13.2 min, p < 0.001) and mean dose (510 vs. 1549 Gycm2, p < 0.001) significantly. Procedural parameters were similar in the two groups. One conservatively treated groin complication occurred (1.3%). CONCLUSIONS: Radiation exposure can be significantly reduced by using the novel NFCV technology in addition to standard AF ablation technologies without negative effects on procedure durations, success rates, or complication rates. With the use of the technology, abandonment of lead protection for EP staff is possible following transseptal puncture.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, DRK Kliniken Berlin Westend, Spandauer Damm 130, 14050, Berlin, Germany. sascha.rolf@web.de.
- Leipzig Heart Institute, LHI, Heart Center, Leipzig, Germany.
- Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany.
Zitieren
APA
Rolf, S., Schoene, K., Kircher, S., Dinov, B., Bertagnolli, L., Bollmann, A., Richter, S., Arya, A., Hindricks, G., & Sommer, P. (2019). Catheter ablation of atrial fibrillation with nonfluoroscopic catheter visualization—a prospective randomized comparison. Journal of Interventional Cardiac Electrophysiology, 54(1), 35-42. https://doi.org/10.1007/s10840-018-0446-8
Vancouver
Rolf S, Schoene K, Kircher S, Dinov B, Bertagnolli L, Bollmann A, et al. Catheter ablation of atrial fibrillation with nonfluoroscopic catheter visualization—a prospective randomized comparison. Journal of Interventional Cardiac Electrophysiology. 2019;54(1):35-42. doi:10.1007/s10840-018-0446-8
BibTeX
@article{Rolf2019,
author = {Rolf, Sascha and Schoene, Katharina and Kircher, Simon and Dinov, Boris and Bertagnolli, Livio and Bollmann, Andreas and Richter, Sergio and Arya, Arash and Hindricks, Gerhard and Sommer, Philipp},
title = {Catheter ablation of atrial fibrillation with nonfluoroscopic catheter visualization—a prospective randomized comparison},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2019},
volume = {54},
number = {1},
pages = {35--42},
doi = {10.1007/s10840-018-0446-8}
}