EUVIMEDEUVIMED entdecken
Crossref

One-year follow-up of implantable Collamer lens in myopic patients

Ruby Abu Nassar iD, Hazim Mesmar, Saadat Amireh, Mahdi Abdul Baqi, Abdallah Herzallah, Mohd Abu Dabat, Saif Aldeen Alryalat, Almutez Gharaibeh

International Ophthalmology · 06.08.2026 · 46 (1)

DOI: 10.1007/s10792-026-04199-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 06.08.2026. Verfasst von Ruby Abu Nassar und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, The University of Jordan, Amman, Jordan. rubyroza1998@gmail.com. Hauptthemen laut MEDLINE: Visual Acuity, Phakic Intraocular Lenses, Refraction, Ocular, Lens Implantation, Intraocular. Die Arbeit nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the outcomes of Evolution (EVO) Implantable Collamer Lens (ICL) V4c implantation in patients with high myopia, emphasizing the enhancement of visual acuity, refractive error correction, and ocular health parameters. METHODS: The study sample included 91 eyes of 52 patients with high myopia (Preoperative spherical equivalent (SE) ≤ - 5 diopters (D)) who underwent EVO ICL V4c implantation between 2017 and 2020. Data were collected preoperatively and at one, six, and 12 months postoperatively. Evaluated parameters included uncorrected and corrected distance visual acuity (UDVA and CDVA), spherical equivalent (SE), sphere power, cylinder power, intraocular pressure (IOP), endothelial cell density (ECD), central corneal thickness (CCT), and anterior chamber measurements. A statistically significant difference was defined as p 21 mmHg). No eyes lost ≥ 2 lines of CDVA, while 20.0% gained ≥ 2 lines. The safety and efficacy indices were 1.17 ± 0.31 and 1.05 ± 0.29, respectively. CONCLUSION: EVO ICL V4c implantation is a safe and effective procedure for correcting high myopia, providing significant and sustained improvement in visual and refractive outcomes with favorable safety, refractive stability, and acceptable postoperative anatomical changes during one year of follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityPhakic Intraocular LensesRefraction, OcularLens Implantation, IntraocularMyopiaHumansFemaleFollow-Up StudiesAdultMaleIntraocular PressureYoung AdultTime FactorsRetrospective Studies

Stichwörter der Autor:innen

Corneal healthEndothelial cell density (ECD)High myopiaImplantable Collamer lens (ICL)Intraocular pressure (IOP)Refractive errorVisual acuity

Autor:innen und Institutionen

  • School of Medicine, The University of Jordan, Amman, Jordan. rubyroza1998@gmail.com.
  • School of Medicine, The University of Jordan, Amman, Jordan.
  • Ophthalmology, Special Surgery, Medicine, Al Shami Eye Center, Amman, Jordan.
  • Department of Ophthalmology, University of Colorado School of Medicine, Sue Anschutz-Rodgers Eye Center, Aurora, CO, USA.
  • Ophthalmology, Special Surgery, Medicine, The University of Jordan, Amman, Jordan.

ORCID-Profile: Ruby Abu Nassar

Zitieren

APA

Abu Nassar, R., Mesmar, H., Amireh, S., Abdul Baqi, M., Herzallah, A., Abu Dabat, M., Alryalat, S. A., & Gharaibeh, A. (2026). One-year follow-up of implantable Collamer lens in myopic patients. International Ophthalmology, 46(1). https://doi.org/10.1007/s10792-026-04199-0

Vancouver

Abu Nassar R, Mesmar H, Amireh S, Abdul Baqi M, Herzallah A, Abu Dabat M, et al. One-year follow-up of implantable Collamer lens in myopic patients. International Ophthalmology. 2026;46(1). doi:10.1007/s10792-026-04199-0

BibTeX
@article{AbuNassar2026,
  author = {Abu Nassar, Ruby and Mesmar, Hazim and Amireh, Saadat and Abdul Baqi, Mahdi and Herzallah, Abdallah and Abu Dabat, Mohd and Alryalat, Saif Aldeen and Gharaibeh, Almutez},
  title = {One-year follow-up of implantable Collamer lens in myopic patients},
  journal = {International Ophthalmology},
  year = {2026},
  volume = {46},
  number = {1},
  doi = {10.1007/s10792-026-04199-0}
}
Kostenlos starten →