Evaluation of ocular surface retention of artificial tears by scintigraphy

Sena Esra Günay, Esra Arzu Gencoglu, Caner İncekaş, Dilek Dursun Altınörs

International Ophthalmology · 22.07.2026 · 46 (1)

DOI: 10.1007/s10792-026-04183-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 22.07.2026. Verfasst von Sena Esra Günay und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Department of Ophthalmology, Başkent University, Ankara, Turkey. sena.gunay44@gmail.com. Hauptthemen laut MEDLINE: Radionuclide Imaging, Lubricant Eye Drops, Lacrimal Apparatus, Tears. Die Arbeit nennt 21 Literaturangaben. Gefördert von: Baskent Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the early phase ocular surface retention of five artificial tear formulations using lacrimal scintigraphy. Materials and methods Sixteen participants (25–42 years) without ocular or systemic disease were enrolled between January 2023 and January 2025, and both eyes were included. Each subject attended three alternate-day sessions and received one Tc-99 m–labeled drop (150 µCi) per eye per session according to predefined formulation pairs: HP guar + sodium hyaluronate (SH) versus saline; trehalose + SH versus dexpanthenol + SH; and SH alone versus polyvinyl alcohol + povidone. Ten-minute dynamic lacrimal scintigraphy was performed following each instillation to evaluate early-phase pre-corneal retention dynamics. Regions of interest were automatically tracked and manually corrected when required. Absolute scintigraphic counts and baseline-normalized 5/0-min and 10/0-min ratios were calculated. A total of 48 dynamic scans were analyzed using linear mixed-effects models with Dunn–Bonferroni post-hoc testing.

Results

Scintigraphic counts decreased significantly over time ( p < 0.001), with a significant overall difference among formulations ( p = 0.006) and no group × time interaction ( p = 0.279). Baseline-normalized ratios similarly demonstrated significant group and time effects (each p < 0.001). HP guar + SH showed greater normalized retention than saline ( p = 0.031), and trehalose + SH likewise exceeded saline ( p = 0.003). HP guar + SH demonstrated the highest overall retention across formulations and showed a numerical advantage over dexpanthenol + SH (MD = 0.117), though not statistically significant ( p = 0.155).

Conclusions

Polymer–hyaluronate combinations, particularly HP guar + SH and trehalose + SH, demonstrated greater early-phase ocular surface retention dynamics compared with saline and several other tested formulations within the observed imaging period. HP guar + SH showed the highest overall retention profile among the evaluated preparations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radionuclide ImagingLubricant Eye DropsLacrimal ApparatusTearsDry Eye SyndromesCorneaHumansAdultFemaleMaleHyaluronic AcidPantothenic AcidMannansPolysaccharides

Stichwörter der Autor:innen

Artificial tearDry eyeLacrimal scintigraphyOcular surface retentionTear film

Substanzen

Lubricant Eye DropsHyaluronic AcidPantothenic Aciddexpanthenolhydroxypropyl guarMannansPolysaccharides

Autor:innen und Institutionen

  • Faculty of Medicine, Department of Ophthalmology, Başkent University, Ankara, Turkey. sena.gunay44@gmail.com.
  • Faculty of Medicine, Department of Nuclear Medicine, Başkent University, Ankara, Turkey.
  • Faculty of Medicine, Department of Biostatistics, Başkent University, Ankara, Turkey.
  • Faculty of Medicine, Department of Ophthalmology, Başkent University, Ankara, Turkey.

Förderung

  • Baskent Üniversitesi

Zitieren

APA

Günay, S. E., Gencoglu, E. A., İncekaş, C., & Altınörs, D. D. (2026). Evaluation of ocular surface retention of artificial tears by scintigraphy. International Ophthalmology, 46(1). https://doi.org/10.1007/s10792-026-04183-8

Vancouver

Günay SE, Gencoglu EA, İncekaş C, Altınörs DD. Evaluation of ocular surface retention of artificial tears by scintigraphy. International Ophthalmology. 2026;46(1). doi:10.1007/s10792-026-04183-8

BibTeX
@article{Gnay2026,
  author = {Günay, Sena Esra and Gencoglu, Esra Arzu and İncekaş, Caner and Altınörs, Dilek Dursun},
  title = {Evaluation of ocular surface retention of artificial tears by scintigraphy},
  journal = {International Ophthalmology},
  year = {2026},
  volume = {46},
  number = {1},
  doi = {10.1007/s10792-026-04183-8}
}
Kostenlos starten →