EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Safety and efficacy of silicone intubation compared to standard techniques in endoscopic dacryocystorhinostomy: a systematic review and meta-analysis

Areej Dar, Amna Amir Jalal, Muhammad Ibrahim, Khudija Sadia, Hamza Irfan, Zuha Tariq, Rameez Qasim, Ghina Khalid, Anas Nasir, Dania Hussain, Barka Sajid, Rabia Nizam und 3 weitere

International Ophthalmology · 15.07.2026 · 46 (1)

DOI: 10.1007/s10792-026-04166-9 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift International Ophthalmology, online erschienen am 15.07.2026. Verfasst von Areej Dar und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Shaikh Khalifa Bin Zayed Al Nahyan Medical and Dental College, Lahore, Pakistan. Hauptthemen laut MEDLINE: Dacryocystorhinostomy, Intubation, Endoscopy, Nasolacrimal Duct. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Primary Acquired nasolacrimal duct obstruction (PANDO) is a lacrimal drainage disorder, commonly seen in adults. Endoscopic Dacryocystorhinostomy (EN-DCR) is a widely adopted surgical procedure for treatment of nasolacrimal duct obstruction. Silicon intubation is a technique, which involves inserting a soft silicone stent to keep the ostium patent post operatively. METHODS: This meta-analysis followed Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) 2020 guidelines, with searches across 4 databases. Primary outcomes were overall success rate, and overall failure rate. Secondary outcomes included granulations/intracanalicular obstruction (ICO) threats, hemorrhage, anatomical failure, functional failure, recurrent symptoms/epiphora, and cicatricial stenosis/post-procedural restenosis. Data were analyzed using R software version 4.3. Heterogeneity was assessed using the I2 statistic. RESULTS: From 3,974 studies initially, 20 studies were selected in the final review, in which 17 were RCTs and 3 observational studies. A statistically significant improvement in surgical success rates, while reducing failure rates were observed in the silicone intubation (stented) group compared to the unstented group. No significant difference was observed in the incidence of restenosis, hemorrhage, functional failure, epiphora or recurrent symptoms. Reduction of anatomical failure was observed. Increase in adverse effects of granulation tissue formation and internal canalicular obstruction were observed. Heterogeneity was low and no publication bias was detected in outcomes. CONCLUSIONS: Silicone intubation during mechanical endoscopic dacryocystorhinostomy (EN-DCR) was associated with improved success and patency rates, as well as lower failure rate. While more resource-intensive, it provides a slightly higher advantage, particularly in recurrent or revision instances, recommending its implementation in routine EN-DCR where possible.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DacryocystorhinostomyIntubationEndoscopyNasolacrimal DuctSiliconesLacrimal Duct ObstructionStentsHumansTreatment Outcome

Stichwörter der Autor:innen

DCR techniquesEndoscopic dacryocystorhinostomyNasolacrimal duct obstructionPANDOSilicon intubation

Substanzen

Silicones

Autor:innen und Institutionen

  • Department of Medicine, Shaikh Khalifa Bin Zayed Al Nahyan Medical and Dental College, Lahore, Pakistan.
  • Department of Medicine, Jinnah Sindh Medical University, Karachi, Pakistan.
  • Department of Medicine, Faisalabad Medical University, Faisalabad, Pakistan.
  • Department of Medicine, Allama Iqbal Medical College, Lahore, Pakistan.
  • Department of Medicine, Sheikh Zayed Medical College, Rahim Yar Khan, Pakistan.
  • Department of Medicine, United Medical and Dental College, Karachi, Pakistan.

Zitieren

APA

Dar, A., Jalal, A. A., Ibrahim, M., Sadia, K., Irfan, H., Tariq, Z., Qasim, R., Khalid, G., Nasir, A., Hussain, D., Sajid, B., Nizam, R., Khalid, M., Tanveer, K., & Rifai, M. (2026). Safety and efficacy of silicone intubation compared to standard techniques in endoscopic dacryocystorhinostomy: a systematic review and meta-analysis. International Ophthalmology, 46(1). https://doi.org/10.1007/s10792-026-04166-9

Vancouver

Dar A, Jalal AA, Ibrahim M, Sadia K, Irfan H, Tariq Z, et al. Safety and efficacy of silicone intubation compared to standard techniques in endoscopic dacryocystorhinostomy: a systematic review and meta-analysis. International Ophthalmology. 2026;46(1). doi:10.1007/s10792-026-04166-9

BibTeX
@article{Dar2026,
  author = {Dar, Areej and Jalal, Amna Amir and Ibrahim, Muhammad and Sadia, Khudija and Irfan, Hamza and Tariq, Zuha and Qasim, Rameez and Khalid, Ghina and Nasir, Anas and Hussain, Dania and Sajid, Barka and Nizam, Rabia and Khalid, Muddassir and Tanveer, Kinza and Rifai, Mohamed},
  title = {Safety and efficacy of silicone intubation compared to standard techniques in endoscopic dacryocystorhinostomy: a systematic review and meta-analysis},
  journal = {International Ophthalmology},
  year = {2026},
  volume = {46},
  number = {1},
  doi = {10.1007/s10792-026-04166-9}
}
Kostenlos starten →