Pulsed accelerated corneal cross-linking for pediatric keratoconus: a prospective study from the Indian subcontinent
International Ophthalmology · 07.07.2026 · 46 (1)
DOI: 10.1007/s10792-026-04157-w ↗Kurz gefasst
Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 07.07.2026. Verfasst von Parul Jain und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology (Guru Nanak Eye Centre), Maulana Azad Medical College, New Delhi, India. Hauptthemen laut MEDLINE: Keratoconus, Corneal Cross-Linking, Visual Acuity, Riboflavin. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the 12 month visual, refractive, and tomographic outcomes of pulsed accelerated corneal collagen cross-linking (PACXL) in children with progressive keratoconus and to determine its safety and efficacy in an Indian pediatric cohort. METHODS: This was a prospective interventional study including 40 eyes of 31 children (< 18 years) with progressive keratoconus and a minimum corneal thickness ≥ 400 µm. All eyes underwent epithelium-off PACXL (9 mW/cm2, 10 s on/5 s off, total 5.4 J/cm2) using the PXL Platinum 330 system. The total procedure time was around 45 min i.e. 30 min of riboflavin instillation and 15 min of UV-A irradiation. Standard postoperative steroid and antibiotic regimens were followed. Outcomes at 12 months included uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA, logMAR), maximum keratometry (Kmax), manifest refraction, pachymetry, endothelial cell density, and postoperative complications. RESULTS: The mean age was 15.4 ± 1.5 years (64.5% male). At 12 months, mean BSCVA improved from 0.31 ± 0.21 to 0.23 ± 0.22 logMAR (p = 0.005) and UCVA from 0.79 ± 0.46 to 0.71 ± 0.47 logMAR (p < 0.001). Mean Kmax decreased from 57.38 ± 6.22 to 56.8 ± 5.6 D. Median refractive cylinder reduced from - 2.0 to - 1.12 D (p = 0.036). Mean thinnest pachymetry declined from 446.15 ± 25.5 to 398.7 ± 43.7 µm (p < 0.001), indicating stromal compaction or possible stromal volume loss. Endothelial cell density remained stable (2843.9 ± 247 → 2828.3 ± 234 cells/mm2; p = 0.092). At 12 months, 34/40 eyes (85%) were stable; 6 eyes (15%) progressed (defined as Kmax increase ≥ 1.0 D), all with advanced baseline disease. Three eyes (7.5%) developed transient sterile infiltrates that resolved with topical steroids. No infectious keratitis or endothelial loss occurred. CONCLUSIONS: Pulsed accelerated CXL provided significant visual improvement and 85% topographic stabilization at 12 months in pediatric keratoconus, with no endothelial toxicity. It offers a time-efficient and safe early-intervention option for children in whom standard protocols are less feasible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology (Guru Nanak Eye Centre), Maulana Azad Medical College, New Delhi, India.
- Shroff Eye Centre, Kailash Colony, New Delhi, India.
- Department of Ophthalmology (Guru Nanak Eye Centre), Maulana Azad Medical College, New Delhi, India. vanditaagr26@gmail.com.
Zitieren
APA
Jain, P., Mehta, A., Arora, R., Gupta, I., Dutta, P., Agrrawal, V., & Mehta, V. (2026). Pulsed accelerated corneal cross-linking for pediatric keratoconus: a prospective study from the Indian subcontinent. International Ophthalmology, 46(1). https://doi.org/10.1007/s10792-026-04157-w
Vancouver
Jain P, Mehta A, Arora R, Gupta I, Dutta P, Agrrawal V, et al. Pulsed accelerated corneal cross-linking for pediatric keratoconus: a prospective study from the Indian subcontinent. International Ophthalmology. 2026;46(1). doi:10.1007/s10792-026-04157-w
BibTeX
@article{Jain2026,
author = {Jain, Parul and Mehta, Arun and Arora, Ritu and Gupta, Isha and Dutta, Paromita and Agrrawal, Vanditaa and Mehta, Vardayani},
title = {Pulsed accelerated corneal cross-linking for pediatric keratoconus: a prospective study from the Indian subcontinent},
journal = {International Ophthalmology},
year = {2026},
volume = {46},
number = {1},
doi = {10.1007/s10792-026-04157-w}
}
EUVIMED