Visual outcomes following implantation of intracorneal rings with sharp and round triangular cross-section designs in keratoconus

Somaye Soleimani, Shiva Pirhadi, Khosrow Jadidi, Ali Mirzajani, Jamile Abolghasemi, Omid Bagherzadeh, Hamidreza Heidari, Jorge L Alio, Hamed Momeni-Moghaddam

International Ophthalmology · 08.04.2026 · 46 (1)

DOI: 10.1007/s10792-026-04038-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 08.04.2026. Verfasst von Somaye Soleimani und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Optometry, University of Montreal, Montreal, Canada. Hauptthemen laut MEDLINE: Keratoconus, Visual Acuity, Refraction, Ocular, Corneal Stroma. Die Arbeit nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare the visual, refractive, corneal curvature, and aberrometry outcomes one year following implantation of two intra-stromal corneal rings (ICRS) with different cross-sectional designs. METHODS: This retrospective longitudinal study included 40 keratoconus eyes implanted with ICRSs with similar characteristics except for their cross-sectional design, Keraring with sharp corners triangular cross-section (n = 20 eyes) and Keratacx Plus with round corners triangular cross-section (n = 20 eyes). The two rings were similar in terms of arc length (355°) and outer diameter (5.7 mm). The uncorrected and corrected distance visual acuity (UDVA & CDVA), refraction, corneal topography, and aberrometry indices were compared before and one year after surgery. RESULTS: Despite a significant change in VA, spherical equivalent, astigmatism, and keratometry readings, there was no statistically significant difference in their mean changes between the two rings. (P > 0.05) The mean corneal asphericity expressed by the Q-value showed a statistically significant change toward less prolateness after surgery and was the only parameter with a significant mean change between the two groups (P = 0.04). In comparing the mean changes of corneal aberrometry indices between two rings, a statistically significant difference was seen for total aberration (P = 0.03), lower order aberrations (LOA, P = 0.03), and defocus (P = 0.03). Subgroup analysis based on keratoconus severity (mild and moderate stages) showed a statistically significant difference in Q-value (P = 0.019), total aberration (P = 0.040), LOA (P = 0.041), and defocus (P = 0.027) only for the moderate keratoconus group between the two rings. CONCLUSIONS: Both rings provided a significant improvement in visual, refractive, and keratometric parameters so that the triangular cross-sectional design of Keratacx Plus with round corners is not superior to Keraring with sharp corners in terms of visual quality and higher order aberrations (HOAs).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

KeratoconusVisual AcuityRefraction, OcularCorneal StromaProstheses and ImplantsProsthesis ImplantationHumansRetrospective StudiesCorneal TopographyMaleFemaleAberrometryAdultProsthesis DesignYoung AdultFollow-Up StudiesTreatment OutcomeCross-Sectional StudiesAdolescent

Stichwörter der Autor:innen

Corneal aberrationsCorneal asphericityCorneal ringCross section designKeraringKeratacxKeratoconus

Autor:innen und Institutionen

  • School of Optometry, University of Montreal, Montreal, Canada.
  • Department of Optometry, School of Rehabilitation, Iran University of Medical Sciences, Tehran, Iran.
  • Vision Health Research Center, Semnan University of Medical Sciences, Semnan, Iran.
  • Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran.
  • Biostatistics Department, School of Public Health, Iran University of Medical Sciences, Tehran, Iran.
  • Didar Eye Clinic, Mashhad, Iran.

Zitieren

APA

Soleimani, S., Pirhadi, S., Jadidi, K., Mirzajani, A., Abolghasemi, J., Bagherzadeh, O., Heidari, H., Alio, J. L., & Momeni-Moghaddam, H. (2026). Visual outcomes following implantation of intracorneal rings with sharp and round triangular cross-section designs in keratoconus. International Ophthalmology, 46(1). https://doi.org/10.1007/s10792-026-04038-2

Vancouver

Soleimani S, Pirhadi S, Jadidi K, Mirzajani A, Abolghasemi J, Bagherzadeh O, et al. Visual outcomes following implantation of intracorneal rings with sharp and round triangular cross-section designs in keratoconus. International Ophthalmology. 2026;46(1). doi:10.1007/s10792-026-04038-2

BibTeX
@article{Soleimani2026,
  author = {Soleimani, Somaye and Pirhadi, Shiva and Jadidi, Khosrow and Mirzajani, Ali and Abolghasemi, Jamile and Bagherzadeh, Omid and Heidari, Hamidreza and Alio, Jorge L and Momeni-Moghaddam, Hamed},
  title = {Visual outcomes following implantation of intracorneal rings with sharp and round triangular cross-section designs in keratoconus},
  journal = {International Ophthalmology},
  year = {2026},
  volume = {46},
  number = {1},
  doi = {10.1007/s10792-026-04038-2}
}
Kostenlos starten →