EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In vivo confocal microscopy (IVCM) analysis of corneal sub-basal nerve plexus (SNP) and corneal sensitivity after micropulse transscleral cyclophotocoagulation (MP-TSCPC) in glaucoma patients

Ho Ming Wong, Lok Yee Tsui, Shuet Yan Poon, Ka Wai Kam, Noel Ching-Yan Chan, Alvin L Young

International Ophthalmology · 2025

DOI: 10.1007/s10792-025-03862-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, 2025. Verfasst von Ho Ming Wong und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, Shatin, New Territories, Hong Kong, China. Hauptthemen laut MEDLINE: Cornea, Intraocular Pressure, Glaucoma, Laser Coagulation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the clinical outcome of micropulse transscleral cyclophotocoagulation (MP-TSCPC) and its effect on corneal sensitivity, as well as corneal nerve parameters using in vivo confocal microscope (IVCM) in eyes with glaucoma. Patients and methods This was a prospective longitudinal study recruiting consecutive glaucoma patients who were scheduled to undergo MP-TSCPC for intraocular pressure (IOP) control in a tertiary center. Pre-operative and postoperative clinical parameters were compared including best-corrected visual acuity, IOP, number of topical glaucoma medication, requirement of oral acetazolamide and corneal sensitivity. Intraoperative and postoperative complications were recorded. Pre-operative and postoperative corneal nerve parameters measured using IVCM were analysed in both operated and non-operated eye. All clinical and imaging parameters were compared longitudinally between baseline, postoperative 2 weeks and 1 month.

Results

Twenty consecutive glaucoma patients who received MP-TSCPC between January 2024 and May 2024 were recruited. Postoperatively, there was a significant reduction in IOP ( p = 0.000) and oral acetazolamide use ( p = 0.001) while visual acuity were maintained ( p = 0.710). However, there were reduced corneal sensitivity ( p = 0.014), decrease in corneal nerve fibre density (CNFD) ( p = 0.017) and corneal nerve branch density (CNBD) ( p = 0.047) as detected by IVCM from baseline to 1 month in the operated eye.

Conclusion

MP-TSCPC is an effective glaucoma treatment in terms of IOP control and reduction of glaucoma medications. However, it may potentially result in reduced corneal sensitivity, corneal nerve fiber density and branch density at postoperative 1 month.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CorneaIntraocular PressureGlaucomaLaser CoagulationCiliary BodyOphthalmic NerveHumansMaleFemaleProspective StudiesMicroscopy, ConfocalMiddle AgedVisual AcuityAgedScleraFollow-Up StudiesNerve FibersAdult

Stichwörter der Autor:innen

CorneaCorneal nerve densityCorneal sensitivityIn-vivo confocal microscopy (IVCM)Micropulse transscleral cyclophotocoagulation(MP-TSCPC)Neurotrophic keratopathy

Autor:innen und Institutionen

  • Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, Shatin, New Territories, Hong Kong, China.
  • Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Ma Liu Shui, Hong Kong, China.
  • Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, Shatin, New Territories, Hong Kong, China. noelccy@gmail.com.
  • Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Ma Liu Shui, Hong Kong, China. noelccy@gmail.com.
  • Department of Ophthalmology and Visual Sciences, Prince of Wales Hospital, 30 Ngan Shing Street, Shatin, New Territories, Hong Kong, China. noelccy@gmail.com.

Zitieren

APA

Wong, H. M., Tsui, L. Y., Poon, S. Y., Kam, K. W., Chan, N. C., & Young, A. L. (2025). In vivo confocal microscopy (IVCM) analysis of corneal sub-basal nerve plexus (SNP) and corneal sensitivity after micropulse transscleral cyclophotocoagulation (MP-TSCPC) in glaucoma patients. International Ophthalmology. https://doi.org/10.1007/s10792-025-03862-2

Vancouver

Wong HM, Tsui LY, Poon SY, Kam KW, Chan NC, Young AL. In vivo confocal microscopy (IVCM) analysis of corneal sub-basal nerve plexus (SNP) and corneal sensitivity after micropulse transscleral cyclophotocoagulation (MP-TSCPC) in glaucoma patients. International Ophthalmology. 2025. doi:10.1007/s10792-025-03862-2

BibTeX
@article{Wong2025,
  author = {Wong, Ho Ming and Tsui, Lok Yee and Poon, Shuet Yan and Kam, Ka Wai and Chan, Noel Ching-Yan and Young, Alvin L},
  title = {In vivo confocal microscopy (IVCM) analysis of corneal sub-basal nerve plexus (SNP) and corneal sensitivity after micropulse transscleral cyclophotocoagulation (MP-TSCPC) in glaucoma patients},
  journal = {International Ophthalmology},
  year = {2025},
  doi = {10.1007/s10792-025-03862-2}
}
Kostenlos starten →