Comparison of corneal pachymetry evolution after accelerated corneal crosslinking in keratoconus eyes using anterior segment optical coherence tomography and Scheimpflug imaging
International Ophthalmology · 2025
DOI: 10.1007/s10792-025-03763-4 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Ophthalmology, 2025. Verfasst von Antonia Lang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Saarland University Medical Center, Kirrberger Straße, Building 22, 66424, Homburg, Germany. anla00014@stud.unisaarland.…. Hauptthemen laut MEDLINE: Keratoconus, Tomography, Optical Coherence, Corneal Pachymetry, Cross-Linking Reagents. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes.
Abstract (Originalsprache)
Purpose
This retrospective clinical study compared longitudinal corneal pachymetry measurement evolution after accelerated corneal crosslinking (A-CXL, 9 mW/cm 2 , 10 min) in keratoconus (KC) eyes as measured by Pentacam HR Scheimpflug imaging (Oculus, Germany) and Casia 2 (Tomey, Japan) anterior segment optical coherence tomography (AS-OCT).
Methods
218 eyes covering the full topographic KC (TKC) severity spectrum that underwent A-CXL between 2017 and 2021 were examined at five time points (before, 6 weeks, 6 months, 1 year after A-CXL and at the latest follow-up) using both Pentacam HR and Casia 2. Central (CCT) and thinnest (TCT) corneal thickness were assessed. Corneal densitometry and TKC classification were assessed by Pentacam HR only. Intraoperative CCT evolution was monitored using ultrasound (Pachymeter SP-3000, Tomey, Japan) to ensure that CCT did not fall below 400 µm.
Results
CCT and TCT measured by Pentacam HR were significantly lower than preoperatively during the first postoperative year, while Casia 2 CCT and TCT measurements were not significantly lower than preoperatively at any time. The highest agreement of Pentacam HR and Casia 2 measurements occurred six weeks after A-CXL. Corneal densitometry peaked six weeks after A-CXL and decreased thereafter without reaching pre-A-CXL values. Ultrasound revealed significant CCT thinning during A-CXL.
Conclusion
Corneal Scheimpflug and AS-OCT based thickness measurements are not interchangeable. Corneal thinning after A-CXL detected by Pentacam HR was not observed in Casia 2 measurements. Since higher densitometry values did not correlate with a greater inter-device measurement difference, Scheimpflug-based corneal thickness measurements should be interpreted cautiously during the first year after A-CXL.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Saarland University Medical Center, Kirrberger Straße, Building 22, 66424, Homburg, Germany. anla00014@stud.unisaarland.de.
- Department of Ophthalmology, Saarland University Medical Center, Kirrberger Straße, Building 22, 66424, Homburg, Germany.
Förderung
- Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes
Zitieren
APA
Lang, A., Seitz, B., Munteanu, C., & Flockerzi, E. (2025). Comparison of corneal pachymetry evolution after accelerated corneal crosslinking in keratoconus eyes using anterior segment optical coherence tomography and Scheimpflug imaging. International Ophthalmology. https://doi.org/10.1007/s10792-025-03763-4
Vancouver
Lang A, Seitz B, Munteanu C, Flockerzi E. Comparison of corneal pachymetry evolution after accelerated corneal crosslinking in keratoconus eyes using anterior segment optical coherence tomography and Scheimpflug imaging. International Ophthalmology. 2025. doi:10.1007/s10792-025-03763-4
BibTeX
@article{Lang2025,
author = {Lang, Antonia and Seitz, Berthold and Munteanu, Cristian and Flockerzi, Elias},
title = {Comparison of corneal pachymetry evolution after accelerated corneal crosslinking in keratoconus eyes using anterior segment optical coherence tomography and Scheimpflug imaging},
journal = {International Ophthalmology},
year = {2025},
doi = {10.1007/s10792-025-03763-4}
}
EUVIMED