EUVIMEDEUVIMED entdecken
Vergleichsstudie

Influence of suture thickness on clinical outcomes in gonioscopy-assisted transluminal trabeculotomy: a comparative analysis of 5–0 and 6–0 polypropylene sutures

Enver Mirza, Gunsu Deniz Mirza, Selman Belviranli, Mehmet Okka

International Ophthalmology · 2025

DOI: 10.1007/s10792-025-03682-4 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift International Ophthalmology, 2025. Verfasst von Enver Mirza und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine, Necmettin Erbakan University, Selçuklu, Konya, 42800, Turkey. envermirza@gmail.com. Hauptthemen laut MEDLINE: Trabeculectomy, Gonioscopy, Sutures, Glaucoma, Open-Angle. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the clinical results of Gonioscopy-Assisted Transluminal Trabeculotomy (GATT) performed with 5-0 or 6-0 polypropylene sutures and whether it makes a difference in anterior chamber (AC) morphology. METHODS: The file records of patients with primary open-angle glaucoma or pseudoexfoliation glaucoma who underwent GATT with 5-0 or 6-0 polypropylene sutures were reviewed. Patients were divided into two groups (GATT with 5-0 polypropylene suture: Group 1 vs. GATT with 6-0 polypropylene suture: Group 2). The clinical results of GATT, intraocular pressure (IOP) values, and parameters measured with Pentacam HR Scheimpflug camera system including anterior chamber angle (ACA), anterior chamber depth (ACD), anterior chamber volume (ACV), central corneal thickness (CCT), and pupil diameter (PD) of two groups at preoperative period, postoperative 1st, 3rd, and 6th months were compared. RESULTS: A total of 41 patients were included in the study (Group 1: n = 21, Group 2: n = 20). Approximately 60% reduction in IOP was detected in both groups and the rate of IOP reduction at each visit was similar between the two groups (p > 0.05 in all). It was determined that there were no differences in AC parameters including ACA, ACD, ACV, CCT, and PD at any visit in either group. (p > 0.05 in all). Also, there was no significant difference in the complication rates between the two groups. CONCLUSION: It was observed that there were no significant differences in terms of success rate, complication rate, and the effect on AC morphology between performing GATT with 5-0 or 6-0 polypropylene sutures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TrabeculectomyGonioscopySuturesGlaucoma, Open-AngleSuture TechniquesPolypropylenesExfoliation SyndromeHumansMaleFemaleIntraocular PressureAgedRetrospective StudiesMiddle AgedTreatment OutcomeFollow-Up StudiesAged, 80 and over

Stichwörter der Autor:innen

Ab-interno trabeculotomyGonioscopy-assisted transluminal trabeculotomyMinimally invasive glaucoma surgeryPolypropylene sutureScheimpflug camera

Substanzen

Polypropylenes

Autor:innen und Institutionen

  • Department of Ophthalmology, Faculty of Medicine, Necmettin Erbakan University, Selçuklu, Konya, 42800, Turkey. envermirza@gmail.com.
  • Clinic of Ophthalmology, University of Health Sciences, Beyhekim Training and Research Hospital, Selçuklu, Konya, Turkey.
  • Department of Ophthalmology, Faculty of Medicine, Necmettin Erbakan University, Selçuklu, Konya, 42800, Turkey.

Zitieren

APA

Mirza, E., Mirza, G. D., Belviranli, S., & Okka, M. (2025). Influence of suture thickness on clinical outcomes in gonioscopy-assisted transluminal trabeculotomy: a comparative analysis of 5–0 and 6–0 polypropylene sutures. International Ophthalmology. https://doi.org/10.1007/s10792-025-03682-4

Vancouver

Mirza E, Mirza GD, Belviranli S, Okka M. Influence of suture thickness on clinical outcomes in gonioscopy-assisted transluminal trabeculotomy: a comparative analysis of 5–0 and 6–0 polypropylene sutures. International Ophthalmology. 2025. doi:10.1007/s10792-025-03682-4

BibTeX
@article{Mirza2025,
  author = {Mirza, Enver and Mirza, Gunsu Deniz and Belviranli, Selman and Okka, Mehmet},
  title = {Influence of suture thickness on clinical outcomes in gonioscopy-assisted transluminal trabeculotomy: a comparative analysis of 5–0 and 6–0 polypropylene sutures},
  journal = {International Ophthalmology},
  year = {2025},
  doi = {10.1007/s10792-025-03682-4}
}
Kostenlos starten →