EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Effects of autologous serum and artificial tears on corneal sensation and tear film stability in patients with mild to moderate xerophthalmia after cataract surgery

Ying Wang, Chun Xiao, Hui Niu, Jun Li, Huimin Rao, Ji'an Li

International Ophthalmology · 24.01.2025 · 45 (1)

DOI: 10.1007/s10792-024-03402-4 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift International Ophthalmology, online erschienen am 24.01.2025. Verfasst von Ying Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Second Department of Ophthalmology, The First People's Hospital of Aksu, Aksu, 843000, Xinjiang Autonomous Region, China. wangyingfpha@puxin-edu.cn. Hauptthemen laut MEDLINE: Cataract Extraction, Cornea, Lubricant Eye Drops, Postoperative Complications. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: We aimed to evaluate the effects of autologous serum plus artificial tears on corneal sensation and tear film stability in patients with mild to moderate xerophthalmia after cataract surgery. METHODS: A total of 150 patients with mild to moderate xerophthalmia after one-time cataract surgery from March 2022 to September 2023 were selected and randomly divided into a control group (n = 75) and a study group (n = 75). The control group was treated with artificial tears (polyvinyl alcohol eye drops), while the study group was given autologous serum plus artificial tears. The treatment lasted for four weeks in both groups. The clinical efficacy was observed and adverse reactions were recorded. RESULTS: The clinical effective rate of the study group was higher than that of the control group (96.00% versus 86.67%) (χ2 = 4.127, P 0.05). CONCLUSIONS: Autologous serum plus artificial tears can improve the corneal sensation and tear film stability and alleviate inflammatory responses without increasing adverse reactions in patients with mild to moderate xerophthalmia after cataract surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cataract ExtractionCorneaLubricant Eye DropsPostoperative ComplicationsSensationSerumXerophthalmiaAgedFemaleHumansMaleMiddle AgedFollow-Up StudiesOphthalmic SolutionsTears

Stichwörter der Autor:innen

Artificial tearCataract surgerySerumXerophthalmia

Substanzen

Lubricant Eye DropsOphthalmic Solutions

Autor:innen und Institutionen

  • Second Department of Ophthalmology, The First People's Hospital of Aksu, Aksu, 843000, Xinjiang Autonomous Region, China. wangyingfpha@puxin-edu.cn.
  • Second Department of Ophthalmology, The First People's Hospital of Aksu, Aksu, 843000, Xinjiang Autonomous Region, China.

Zitieren

APA

Wang, Y., Xiao, C., Niu, H., Li, J., Rao, H., & Li, J. (2025). Effects of autologous serum and artificial tears on corneal sensation and tear film stability in patients with mild to moderate xerophthalmia after cataract surgery. International Ophthalmology, 45(1). https://doi.org/10.1007/s10792-024-03402-4

Vancouver

Wang Y, Xiao C, Niu H, Li J, Rao H, Li J. Effects of autologous serum and artificial tears on corneal sensation and tear film stability in patients with mild to moderate xerophthalmia after cataract surgery. International Ophthalmology. 2025;45(1). doi:10.1007/s10792-024-03402-4

BibTeX
@article{Wang2025,
  author = {Wang, Ying and Xiao, Chun and Niu, Hui and Li, Jun and Rao, Huimin and Li, Ji'an},
  title = {Effects of autologous serum and artificial tears on corneal sensation and tear film stability in patients with mild to moderate xerophthalmia after cataract surgery},
  journal = {International Ophthalmology},
  year = {2025},
  volume = {45},
  number = {1},
  doi = {10.1007/s10792-024-03402-4}
}
Kostenlos starten →