EUVIMEDEUVIMED entdecken
Crossref

Does blepharospasm effect biometric parameters and intraocular lens power calculations?

Ibrahim Basol, Hatice Deniz Ilhan

International Ophthalmology · 2024

DOI: 10.1007/s10792-024-03277-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, 2024. Verfasst von Ibrahim Basol und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Antalya City Hospital, Antalya, 07080, Turkey. dr.basol@gmail.com. Hauptthemen laut MEDLINE: Blepharospasm, Lenses, Intraocular, Biometry, Corneal Topography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To investigate the effect of botulinum toxin-A (BTX-A) treatment on corneal topography, ocular biometry and keratometry in patients with benign essential blepharospasm (BEB) and hemifacial spasm (HFS). METHODS: This study comprised 66 eyes of 33 patients with BEB and 5 eyes of 5 patients with HFS who underwent BTX-A injections consecutively. Refractive error values, tear break-up time (TBUT), corneal topography [corneal power of flat axis (K1) and steep axis (K2), mean corneal power (Km), corneal astigmatism (K2-K1)] and ocular optical biometry [axial length (AL), anterior chamber depth (ACD)] were recorded before BTX-A treatment and 1 month after BTX-A treatment. The researchers calculated the expected emmetropic intraocular lens power (emm-IOL) using the SRK-T, Holladay, Hoffer-Q and Haigis formulas at each examination. RESULTS: K1 (43.48 ± 2.02 vs. 43.57 ± 2.08, p = 0.036), Km (43.91 ± 1.99 vs. 43.99 ± 2.06, p = 0.024) and ACD (3.22 (2.77-3.76) vs. 3.41 (2.99-4.02), p 0.05). CONCLUSIONS: Our study is the first in the literature to compare optic biometry data and intraocular lens power calculation formulas before and after BTX-A injection in eyes with BEB and HFS. BTX-A injection could play an important role in changing the keratometric and ACD values. It should be considered that IOL power calculations that might be unpredictable due to blepharospasm, so repeated measurements and especially measurements after releasing the spasm with BTX-A injections, are necessary in BEB and HFS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BlepharospasmLenses, IntraocularBiometryCorneal TopographyBotulinum Toxins, Type ARefraction, OcularCorneaHumansMaleFemaleMiddle AgedAgedNeuromuscular AgentsAdultHemifacial SpasmVisual Acuity

Stichwörter der Autor:innen

BiometryBlepharospasmBotulinum neurotoxin-aIntraocular lensTopography

Substanzen

Botulinum Toxins, Type ANeuromuscular Agents

Autor:innen und Institutionen

  • Department of Ophthalmology, Antalya City Hospital, Antalya, 07080, Turkey. dr.basol@gmail.com.
  • Department of Ophthalmology, Akdeniz University, Konyaalti, Antalya, 07070, Turkey.

Zitieren

APA

Basol, I., & Ilhan, H. D. (2024). Does blepharospasm effect biometric parameters and intraocular lens power calculations?. International Ophthalmology. https://doi.org/10.1007/s10792-024-03277-5

Vancouver

Basol I, Ilhan HD. Does blepharospasm effect biometric parameters and intraocular lens power calculations?. International Ophthalmology. 2024. doi:10.1007/s10792-024-03277-5

BibTeX
@article{Basol2024,
  author = {Basol, Ibrahim and Ilhan, Hatice Deniz},
  title = {Does blepharospasm effect biometric parameters and intraocular lens power calculations?},
  journal = {International Ophthalmology},
  year = {2024},
  doi = {10.1007/s10792-024-03277-5}
}
Kostenlos starten →