Tear film stability in patients with symptoms of dry eye after instillation of dual polymer hydroxypropyl guar/sodium hyaluronate vs single polymer sodium hyaluronate
International Ophthalmology · 2024
DOI: 10.1007/s10792-024-03061-5 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift International Ophthalmology, 2024. Verfasst von Piotr Kanclerz und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Hygeia Clinic, ul. Jaśkowa Dolina 57, 80-286, Gdańsk, Poland. p.kanclerz@gumed.edu.pl. Hauptthemen laut MEDLINE: Dry Eye Syndromes, Hyaluronic Acid, Tears, Ophthalmic Solutions. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: Alcon.
Abstract (Originalsprache)
PURPOSE: This study evaluated the tear film stability in patients with symptoms of dry eye after installation of dual polymer hydroxypropyl guar/sodium hyaluronate (DPHG/SH) vs single polymer SH. METHODS: Patients with recently diagnosed mild to moderate dry eye disease (OSDI score 23-32 points) were included. For each patient, the right eye was randomized to receive DPHG/SH or 0.15% SH. Just after the administration of the drop to the right eye, the fellow eye received the other eye drop. The first non-invasive Keratograph first break-up time (NIKBUT), average NIKBUT and tear meniscus height (TMH) were measured before administration of the eye drops, at 1-min, 15 min, 30 min, 60 min, 90 min, and 120 min after instillation. RESULTS: A total of 29 patients aged 22.8 ± 2.2 years participated in the study (21 women). No differences between the eye receiving DPHG/SH and single polymer SH were observed for the first NIKBUT (p = 0.45) and average NIKBUT (p = 0.24) variables at any time point. Both DPHG/SH and single polymer SH increased the TMH (p of time effect < 0.001), but with no difference between groups (p = 0.95). CONCLUSION: Both DPHG/SH and single polymer SH solutions provide lubrication of the eye surface, however, with no difference in NIKBUT and TMH evaluations for up to two hours following administration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Hygeia Clinic, ul. Jaśkowa Dolina 57, 80-286, Gdańsk, Poland. p.kanclerz@gumed.edu.pl.
- Helsinki Retina Research Group, University of Helsinki, Helsinki, Finland. p.kanclerz@gumed.edu.pl.
- Department of Ophthalmology, Hygeia Clinic, ul. Jaśkowa Dolina 57, 80-286, Gdańsk, Poland.
Förderung
- Alcon
Zitieren
APA
Kanclerz, P., Bazylczyk, N., & Radomski, S. A. (2024). Tear film stability in patients with symptoms of dry eye after instillation of dual polymer hydroxypropyl guar/sodium hyaluronate vs single polymer sodium hyaluronate. International Ophthalmology. https://doi.org/10.1007/s10792-024-03061-5
Vancouver
Kanclerz P, Bazylczyk N, Radomski SA. Tear film stability in patients with symptoms of dry eye after instillation of dual polymer hydroxypropyl guar/sodium hyaluronate vs single polymer sodium hyaluronate. International Ophthalmology. 2024. doi:10.1007/s10792-024-03061-5
BibTeX
@article{Kanclerz2024,
author = {Kanclerz, Piotr and Bazylczyk, Natasza and Radomski, Szymon Adam},
title = {Tear film stability in patients with symptoms of dry eye after instillation of dual polymer hydroxypropyl guar/sodium hyaluronate vs single polymer sodium hyaluronate},
journal = {International Ophthalmology},
year = {2024},
doi = {10.1007/s10792-024-03061-5}
}
EUVIMED