Passive CAP-VAC: a simple and safe technique to clean the posterior capsule
International Ophthalmology · 2023
DOI: 10.1007/s10792-023-02848-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Ophthalmology, 2023. Verfasst von Andrea Corsi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmogy Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy. Hauptthemen laut MEDLINE: Lens Capsule, Crystalline, Cataract, Cataract Extraction, Phacoemulsification. Die Arbeit nennt 35 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To describe a new and less risky technique for the cleaning of posterior capsule during phacoemulsification called passive cap vac. METHOD: Passive cap vac consisted in the removal of residual posterior capsule opacities using a disconnected 0.3 mm aspiration cannula. The hole of the aspiration cannula was faced toward posterior capsule and gently rubbed against it to achieve a complete cleaning of posterior capsule. The video of the technique is available online. RESULT: With this new technique, the aspiration was ruled by the gravity and by the height of the balanced saline solution (BSS), in addition the Venturi's effect and the absence of active aspiration beyond the cannula avoided an excessive aspiration of posterior capsule. CONCLUSION: Passive cap vac allowed to clean posterior capsule using softer forces than traditional way, minimizing the risk of capsular tear.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ophthalmogy Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy.
- Ophthalmogy Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy. isabella.corsi.88@gmail.com.
- Department of Ophthalmology, University of Rome Tor Vergata, Rome, Italy. isabella.corsi.88@gmail.com.
Zitieren
APA
Corsi, A., Corsi, I., & de Paula, A. (2023). Passive CAP-VAC: a simple and safe technique to clean the posterior capsule. International Ophthalmology. https://doi.org/10.1007/s10792-023-02848-2
Vancouver
Corsi A, Corsi I, de Paula A. Passive CAP-VAC: a simple and safe technique to clean the posterior capsule. International Ophthalmology. 2023. doi:10.1007/s10792-023-02848-2
BibTeX
@article{Corsi2023,
author = {Corsi, Andrea and Corsi, Isabella and de Paula, Alessandro},
title = {Passive CAP-VAC: a simple and safe technique to clean the posterior capsule},
journal = {International Ophthalmology},
year = {2023},
doi = {10.1007/s10792-023-02848-2}
}
EUVIMED