EUVIMEDEUVIMED entdecken
Crossref

Passive CAP-VAC: a simple and safe technique to clean the posterior capsule

Andrea Corsi, Isabella Corsi, Alessandro de Paula

International Ophthalmology · 2023

DOI: 10.1007/s10792-023-02848-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, 2023. Verfasst von Andrea Corsi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmogy Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy. Hauptthemen laut MEDLINE: Lens Capsule, Crystalline, Cataract, Cataract Extraction, Phacoemulsification. Die Arbeit nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To describe a new and less risky technique for the cleaning of posterior capsule during phacoemulsification called passive cap vac. METHOD: Passive cap vac consisted in the removal of residual posterior capsule opacities using a disconnected 0.3 mm aspiration cannula. The hole of the aspiration cannula was faced toward posterior capsule and gently rubbed against it to achieve a complete cleaning of posterior capsule. The video of the technique is available online. RESULT: With this new technique, the aspiration was ruled by the gravity and by the height of the balanced saline solution (BSS), in addition the Venturi's effect and the absence of active aspiration beyond the cannula avoided an excessive aspiration of posterior capsule. CONCLUSION: Passive cap vac allowed to clean posterior capsule using softer forces than traditional way, minimizing the risk of capsular tear.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lens Capsule, CrystallineCataractCataract ExtractionPhacoemulsificationHumansLens Implantation, Intraocular

Stichwörter der Autor:innen

Capsular cleaningCapsular surgeryCataractPosterior capsule opacification

Autor:innen und Institutionen

  • Ophthalmogy Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy.
  • Ophthalmogy Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy. isabella.corsi.88@gmail.com.
  • Department of Ophthalmology, University of Rome Tor Vergata, Rome, Italy. isabella.corsi.88@gmail.com.

Zitieren

APA

Corsi, A., Corsi, I., & de Paula, A. (2023). Passive CAP-VAC: a simple and safe technique to clean the posterior capsule. International Ophthalmology. https://doi.org/10.1007/s10792-023-02848-2

Vancouver

Corsi A, Corsi I, de Paula A. Passive CAP-VAC: a simple and safe technique to clean the posterior capsule. International Ophthalmology. 2023. doi:10.1007/s10792-023-02848-2

BibTeX
@article{Corsi2023,
  author = {Corsi, Andrea and Corsi, Isabella and de Paula, Alessandro},
  title = {Passive CAP-VAC: a simple and safe technique to clean the posterior capsule},
  journal = {International Ophthalmology},
  year = {2023},
  doi = {10.1007/s10792-023-02848-2}
}
Kostenlos starten →