EUVIMEDEUVIMED entdecken
Crossref

Fixation stability improvement after occlusion treatment for severe amblyopia

Shu Wang, Leilei Zou, Tian Tian, Aiqin Zhan, Yan Liu, Wen Wen, Hong Liu

International Ophthalmology · 2022-03 · 42 (3) · 1007-1012

DOI: 10.1007/s10792-021-02084-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 19.10.2021. Verfasst von Shu Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China. Hauptthemen laut MEDLINE: Amblyopia. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 11 Literaturangaben. Gefördert von: national natural science foundation of china, shanghai hospital development center, pudong new area municipal health bureau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: To investigate the improvement of fixation stability of severe amblyopia with traditional patching treatment by the MP-1 microperimeter. METHODS: Eighteen patients with severe unilateral amblyopia were enrolled and received prescribed 6 h per day of patching of the fellow eye with optical correction if needed. Fixation test was performed on eighteen severe unilateral amblyopia patients by the MP-1 microperimeter in baseline, 3-month and 6-month after treatment. The bivariate contour ellipse area (BCEA, deg2) was used to quantify fixation stability. RESULTS: The RMANOVA showed that significant differences were found in best-corrected visual acuity (BCVA) between amblyopia eyes/fellow eyes (AE/FE) group (F = 113.52, p 0.05). CONCLUSIONS: The fixation stability in the amblyopic eyes is significantly worse than that of the fellow eyes in patients with unilateral severe amblyopia. The fixation stability became better after 6-month occlusion treatment, but the change of fixation stability was not correlated with visual acuity improvement. These quantitative results highlight the importance of fixation in the mechanism of amblyopia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AmblyopiaFixation, OcularHumansRetinaVisual Acuity

Stichwörter der Autor:innen

AmblyopiaEccentric fixationFixation locationFixation stabilityMP-1 microperimeter

Autor:innen und Institutionen

  • Department of Ophthalmology, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Department of Ophthalmology & Visual Science, Eye & ENT Hospital, Shanghai Medical College, Fudan University, Shanghai, China.
  • State Key Laboratory of Medical Neurobiology, Institutes of Brain Science, Fudan University, Shanghai, China.
  • Key Laboratory of Myopia, Fudan University, Ministry of Health, Shanghai, China.
  • Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai, China.
  • Jinshan Tinglin Hospital, Shanghai, China.

Förderung

  • national natural science foundation of china
  • shanghai hospital development center
  • pudong new area municipal health bureau
  • health and family planning commission of sichuan province

Zitieren

APA

Wang, S., Zou, L., Tian, T., Zhan, A., Liu, Y., Wen, W., & Liu, H. (2022). Fixation stability improvement after occlusion treatment for severe amblyopia. International Ophthalmology, 42(3), 1007-1012. https://doi.org/10.1007/s10792-021-02084-6

Vancouver

Wang S, Zou L, Tian T, Zhan A, Liu Y, Wen W, et al. Fixation stability improvement after occlusion treatment for severe amblyopia. International Ophthalmology. 2022;42(3):1007-1012. doi:10.1007/s10792-021-02084-6

BibTeX
@article{Wang2022,
  author = {Wang, Shu and Zou, Leilei and Tian, Tian and Zhan, Aiqin and Liu, Yan and Wen, Wen and Liu, Hong},
  title = {Fixation stability improvement after occlusion treatment for severe amblyopia},
  journal = {International Ophthalmology},
  year = {2022},
  volume = {42},
  number = {3},
  pages = {1007--1012},
  doi = {10.1007/s10792-021-02084-6}
}
Kostenlos starten →