EUVIMEDEUVIMED entdecken
Crossref

Long-term outcomes of trabeculectomy with ologen implant versus combined viscotrabeculotomy-synechiolysis in uncontrolled uveitic glaucoma

Ahmed S Elwehidy, Nader H L Bayoumi, Amgad El Nokrashy, Sherein M Hagras

International Ophthalmology · 2022-02 · 42 (2) · 411-421

DOI: 10.1007/s10792-021-02057-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 05.10.2021. Verfasst von Ahmed S Elwehidy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Mansoura University, Mansoura, Egypt. Hauptthemen laut MEDLINE: Glaucoma, Trabeculectomy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To compare trabeculectomy with Ologen implant(Trab-Ologen) to combined viscotrabeculotomy-synechiolysis(VTS) in uncontrolled uveitic glaucoma (UG). PATIENTS AND METHODS: A retrospective chart review of 47 patients subjected to VTS(24 eyes) or Trab-ologen(23 eyes) at Mansoura Ophthalmic Center between 2010 and 2016. The patients were evaluated on day 1, week 1, months 1, 3, 6, 12, 18, 24, 30, 36, 42, and 48. RESULTS: The mean ± standard deviation age of patients in the Trab-ologen and VST groups were 38.29 ± 12.5 and 38.91 ± 11.8 years (p = 0.86), respectively. Juvenile Idiopathic arthritis (controlled on methotrexate) was the most common associated systemic disease (3 patients in each group). The mean ± standard deviation of the intraocular pressure (IOP) and IOP-lowering medications preoperatively and at the end of follow up in the Trab-ologen and VST groups were 33.1 ± 2.6 mmHg, 33.2 ± 2.6 mmHg (p = 0.91), 3.4 ± 0.5, 3.4 ± 0.5 (0.90) and 15.4 ± 1.2 mmHg, 13.0 ± 0.9 mmHg (p < 0.001), 0.6 ± 1.1, 0.7 ± 1.2 (p = 0.72), respectively. IOP control was better in the Trab-ologen group till the 30th month when it becomes better in the VST group till the end of follow-up. The most notable complication was a minimal self-limiting hyphema in the VST group. Success rates at the end of follow-up in the Trab-ologen and VST groups were 83% and 78%, respectively. CONCLUSIONS: Trabeculectomy with ologen implant and visco-trabeculotomy-synechiolysis were equally effective in lowering IOP in uncontrolled UG. There was no statistically significant difference in the success rates between the 2 procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlaucomaTrabeculectomyAdultCollagenFollow-Up StudiesGlycosaminoglycansHumansIntraocular PressureMiddle AgedRetrospective StudiesTreatment Outcome

Stichwörter der Autor:innen

Anterior uveitisGlaucomaSynechiolysisTrabeculectomy with ologenViscotrabeculotomy

Substanzen

Glycosaminoglycanscollagen-glycosaminoglycan copolymerCollagen

Autor:innen und Institutionen

  • Faculty of Medicine, Mansoura University, Mansoura, Egypt.
  • Faculty of Medicine, Alexandria University, 311, Horeya Avenue, Sporting, 10th floor, App 1004, Alexandria, Egypt. naderbayoumi@yahoo.com.
  • Faculty of Medicine, Mansoura Ophthalmic Center, Mansoura University, Mansoura, Egypt.

Zitieren

APA

Elwehidy, A. S., Bayoumi, N. H. L., El Nokrashy, A., & Hagras, S. M. (2022). Long-term outcomes of trabeculectomy with ologen implant versus combined viscotrabeculotomy-synechiolysis in uncontrolled uveitic glaucoma. International Ophthalmology, 42(2), 411-421. https://doi.org/10.1007/s10792-021-02057-9

Vancouver

Elwehidy AS, Bayoumi NHL, El Nokrashy A, Hagras SM. Long-term outcomes of trabeculectomy with ologen implant versus combined viscotrabeculotomy-synechiolysis in uncontrolled uveitic glaucoma. International Ophthalmology. 2022;42(2):411-421. doi:10.1007/s10792-021-02057-9

BibTeX
@article{Elwehidy2022,
  author = {Elwehidy, Ahmed S and Bayoumi, Nader H L and El Nokrashy, Amgad and Hagras, Sherein M},
  title = {Long-term outcomes of trabeculectomy with ologen implant versus combined viscotrabeculotomy-synechiolysis in uncontrolled uveitic glaucoma},
  journal = {International Ophthalmology},
  year = {2022},
  volume = {42},
  number = {2},
  pages = {411--421},
  doi = {10.1007/s10792-021-02057-9}
}
Kostenlos starten →