Combined Ab interno viscocanaloplasty (ABiC) in open-angle glaucoma: 12-month outcomes

Kevin Gillmann, Amr Aref, Laëtitia Jessy Niegowski, Jean-Marc Baumgartner

International Ophthalmology · 2021-10 · 41 (10) · 3295-3301

DOI: 10.1007/s10792-021-01891-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Ophthalmology, online erschienen am 20.05.2021. Verfasst von Kevin Gillmann und 3 weiteren Autor:innen. Beteiligte Einrichtung: Ophthalmology Network Organisation, Clinique de L'Oeil SA, Avenue Bois-de-la-Chapelle 35, 1213, Onex, Geneva, Switzerland. kevin.gillmann@wanadoo.fr. Hauptthemen laut MEDLINE: Glaucoma, Open-Angle, Trabeculectomy. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The aim of this study was to analyse the safety profile and efficacy of ab interno viscocanaloplasty (ABiC) through to 12 months post-operatively. METHODS: In this retrospective study, the medical records of all patients who underwent ABiC between September 2015 and December 2019 were analysed. Complete success was defined as a 12-month reduction in intraocular pressure (IOP) ≥ 20% from baseline with no concomitant medications. Qualified success criteria were identical, with no more medications than at baseline. RESULTS: In all, 54 eyes of 41 patients were analysed. Mean IOP decreased from 23.6 ± 7.4 mmHg preoperatively to 14.2 ± 2.9 mmHg (-39.8%; p < 0.001) after 12 months. Concomitantly, the number of anti-glaucoma treatment dropped from 2.9 ± 1.0 to 0.6 ± 1.1 (-79.3%; p < 0.001). Amongst patients with a baseline MD < -12.0 dBs, mean IOP decreased from 22.8 ± 9.8 mmHg to 13.8 ± 4.4 mmHg (p = 0.049), with a concomitant reduction of medications from 2.8 ± 1.3 to 1.2 ± 1.3 (p < 0.001). Complete success at 12 months was achieved in 46% of eyes, and qualified success was achieved in 65% of eyes. Amongst eyes with a baseline MD < -12.0 dBs, 50% achieved complete success, and 83.3% achieved qualified success. A total of 19 eyes (35.2%) were considered surgical failure, all due to uncontrolled IOP. Of them, 7 eyes (13.0%) required further filtering surgery. Twelve post-operative adverse events were observed, with early post-operative IOP spikes being the most common (22.2%). CONCLUSIONS: ABIC achieved a statistically significant reduction in IOP and anti-glaucoma medications through 12 months, while maintaining a favourable safety profile in mild-to-severe open-angle glaucoma.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glaucoma, Open-AngleTrabeculectomyHumansIntraocular PressureRetrospective StudiesTonometry, OcularTreatment Outcome

Stichwörter der Autor:innen

CanaloplastyGlaucomaMIGSSurgeryViscocanalostomyiTrack

Autor:innen und Institutionen

  • Ophthalmology Network Organisation, Clinique de L'Oeil SA, Avenue Bois-de-la-Chapelle 35, 1213, Onex, Geneva, Switzerland. kevin.gillmann@wanadoo.fr.
  • Research Institute of Ophthalmology, Giza, Egypt.
  • Ophthalmology Network Organisation, Clinique de L'Oeil SA, Avenue Bois-de-la-Chapelle 35, 1213, Onex, Geneva, Switzerland.

Zitieren

APA

Gillmann, K., Aref, A., Niegowski, L. J., & Baumgartner, J. M. (2021). Combined Ab interno viscocanaloplasty (ABiC) in open-angle glaucoma: 12-month outcomes. International Ophthalmology, 41(10), 3295-3301. https://doi.org/10.1007/s10792-021-01891-1

Vancouver

Gillmann K, Aref A, Niegowski LJ, Baumgartner JM. Combined Ab interno viscocanaloplasty (ABiC) in open-angle glaucoma: 12-month outcomes. International Ophthalmology. 2021;41(10):3295-3301. doi:10.1007/s10792-021-01891-1

BibTeX
@article{Gillmann2021,
  author = {Gillmann, Kevin and Aref, Amr and Niegowski, Laëtitia Jessy and Baumgartner, Jean-Marc},
  title = {Combined Ab interno viscocanaloplasty (ABiC) in open-angle glaucoma: 12-month outcomes},
  journal = {International Ophthalmology},
  year = {2021},
  volume = {41},
  number = {10},
  pages = {3295--3301},
  doi = {10.1007/s10792-021-01891-1}
}
Kostenlos starten →