Improving radial velocity precision with CARMENES-PLUS
Experimental Astronomy · 2025-10 · 60 (2)
DOI: 10.1007/s10686-025-10020-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Astronomy, online erschienen am 01.09.2025. Verfasst von R. Varas und 27 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Instituto de Astrofísica de Andalucía.
Abstract (Originalsprache)
Context
CARMENES is a dual-channel high-resolution spectrograph at the 3.5 m Calar Alto telescope designed to detect low-mass planets around late-type dwarfs by measuring their radial velocities (RVs). High thermal stability in both the visible (VIS) and near-infrared (NIR) channels is essential to achieve the precision required for these measurements. In particular, stabilising the NIR channel to the millikelvin level, which operates at cryogenic temperatures ( $$\sim$$ 140 K), poses significant engineering challenges.
Purpose
The CARMENES-PLUS project was initiated to improve the instrument’s intrinsic RV precision. In this article, we focus on the thermal stability improvements made to the NIR channel’s cooling system.
Methods
The NIR cooling system was originally conceived to operate with a discontinuous flow of cryogenic nitrogen gas. As part of CARMENES-PLUS, this was upgraded to a continuous flow configuration. Additional changes included the installation of an automatic vacuum system, a proportional control valve, and a pressure regulation system. These upgrades were designed to reduce thermal fluctuations and enhance long-term stability.
Results
The implemented upgrades significantly improved the intrinsic RV precision of the NIR channel. We quantified this improvement using Fabry-Pérot calibration spectra, obtaining an intrinsic RV precision of 0.67 m s $$^{-1}$$ after the interventions, an improvement of nearly 2 m s $$^{-1}$$ . We also assessed the stability of the nightly zero points, finding a reduced scatter of 3.9 m s $$^{-1}$$ post-upgrade, compared to 6.1 m s $$^{-1}$$ before. For a sample of slowly rotating stars ( $$v \sin i_\star \le$$ 2 km s $$^{-1}$$ ), the median scatter decreased from 8.8 m s $$^{-1}$$ to 6.7 m s $$^{-1}$$ after the upgrades.
Conclusions
These results demonstrate that the thermal control upgrades introduced in CARMENES-PLUS have enhanced the NIR channel’s RV performance, bringing it closer to the VIS channel’s stability and reinforcing CARMENES’s capabilities for exoplanet detection around M dwarfs.
Förderung
- Instituto de Astrofísica de Andalucía
Zitieren
APA
Varas, R., Calvo-Ortega, R., Amado, P. J., Becerril, S., Ruh, H., Azzaro, M., Hernández, L., Magán-Madinabeitia, H., Reinhart, S., Maroto-Fernández, D., Helmling, J., Huelmo, Á. L., Benítez, D., López, J. F., Pineda, M., García, J. A., Fuente, J. G. D. L., Marín, J., Hernández, F., …, & Zechmeister, M. (2025). Improving radial velocity precision with CARMENES-PLUS. Experimental Astronomy, 60(2). https://doi.org/10.1007/s10686-025-10020-0
Vancouver
Varas R, Calvo-Ortega R, Amado PJ, Becerril S, Ruh H, Azzaro M, et al. Improving radial velocity precision with CARMENES-PLUS. Experimental Astronomy. 2025;60(2). doi:10.1007/s10686-025-10020-0
BibTeX
@article{Varas2025,
author = {Varas, R. and Calvo-Ortega, R. and Amado, P. J. and Becerril, S. and Ruh, H. and Azzaro, M. and Hernández, L. and Magán-Madinabeitia, H. and Reinhart, S. and Maroto-Fernández, D. and Helmling, J. and Huelmo, Á. L. and Benítez, D. and López, J. F. and Pineda, M. and García, J. A. and Fuente, J. García de la and Marín, J. and Hernández, F. and Aceituno, J. and Caballero, J. A. and Kaminski, A. and Mathar, R. J. and Quirrenbach, A. and Reiners, A. and Ribas, I. and Seifert, W. and Zechmeister, M.},
title = {Improving radial velocity precision with CARMENES-PLUS},
journal = {Experimental Astronomy},
year = {2025},
volume = {60},
number = {2},
doi = {10.1007/s10686-025-10020-0}
}
EUVIMED