EUVIMEDEUVIMED entdecken
Crossref

A stabilized single-reagent TMB method for free chlorine monitoring in drinking water–related matrices

Hao Zhang iD

Environmental Monitoring and Assessment · 05.10.2026 · 198 (11)

DOI: 10.1007/s10661-026-15979-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Monitoring and Assessment, online erschienen am 05.10.2026. Verfasst von Hao Zhang. Beteiligte Einrichtung: Onestep Technologies Inc., Vancouver, Canada. zhang@onestep-technologies.com. Hauptthemen laut MEDLINE: Drinking Water, Chlorine, Environmental Monitoring, Water Pollutants, Chemical. Die Arbeit nennt 14 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous free chlorine monitoring supports drinking water and treated water management, but practical implementation depends on analytical performance as well as reagent handling and fluidic simplicity. This short communication evaluates a stabilized single-reagent tetramethylbenzidine (TMB) method designed as a measurement layer for simplified online monitoring. Quantitative comparison used a controlled benchtop fixed-time absorbance-at-650-nm (A650) readout at 30 s. The dataset comprised 32 paired measurements, including 20 tap-water or finished-water samples and 12 controlled matrix-concentration conditions spanning three defined mineral-background matrices evaluated at four free-chlorine levels each. TMB and N,N-diethyl-p-phenylenediamine (DPD) comparator measurements were performed within 5 min and in triplicate. Deming regression yielded a slope of 0.985 and an intercept of 0.007 mg L⁻1 as Cl2. The mean paired difference (TMB-DPD) was + 0.001 mg L⁻1 and the mean absolute difference was 0.013 mg L⁻1. Precision assessed from the triplicate TMB readings gave a median RSD of 2.4% and a mean RSD of 3.6%. Sealed storage observations further supported the reagent-handling rationale for a stabilized single-reagent format. Together, these results show close agreement with routine DPD measurements across the evaluated drinking water-related matrices and provide a quantitative basis for further translation into a compact monitoring platform.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drinking WaterChlorineEnvironmental MonitoringWater Pollutants, ChemicalBenzidines

Stichwörter der Autor:innen

Analytical agreementColorimetric analysisDPD comparisonDeming regressionRepeatabilityResidual disinfectant

Substanzen

Drinking WaterChlorineWater Pollutants, ChemicalBenzidines3,3',5,5'-tetramethylbenzidine

Autor:innen und Institutionen

  • Onestep Technologies Inc., Vancouver, Canada. zhang@onestep-technologies.com.

ORCID-Profile: Hao Zhang

Zitieren

APA

Zhang, H. (2026). A stabilized single-reagent TMB method for free chlorine monitoring in drinking water–related matrices. Environmental Monitoring and Assessment, 198(11). https://doi.org/10.1007/s10661-026-15979-7

Vancouver

Zhang H. A stabilized single-reagent TMB method for free chlorine monitoring in drinking water–related matrices. Environmental Monitoring and Assessment. 2026;198(11). doi:10.1007/s10661-026-15979-7

BibTeX
@article{Zhang2026,
  author = {Zhang, Hao},
  title = {A stabilized single-reagent TMB method for free chlorine monitoring in drinking water–related matrices},
  journal = {Environmental Monitoring and Assessment},
  year = {2026},
  volume = {198},
  number = {11},
  doi = {10.1007/s10661-026-15979-7}
}
Kostenlos starten →