EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Coupling electrochemical and spectroscopic methods for river water dissolved organic matter characterization

Stefan Platikanov, Abel Palomas, Michelle Cedeño Mata, Romà Tauler, Jorge Villar, Ramon Bragós, Sandra Bermejo, Joaquim Jaumot, Sílvia Lacorte

Environmental Monitoring and Assessment · 2025

DOI: 10.1007/s10661-025-14489-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Monitoring and Assessment, 2025. Verfasst von Stefan Platikanov und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, 08034, Barcelona, Spain. Hauptthemen laut MEDLINE: Rivers, Environmental Monitoring, Water Pollutants, Chemical, Humic Substances. Die Arbeit nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerio de Ciencia e Innovación (MCIN) y la Agencia Estatal de Investigación (AEI) and the European Union 'Next Generation EU/PRTR, Ministerio de Ciencia e Innovación (MCIN) y la Agencia Estatal de Investigación (AEI) and the European Union ‘Next Generation EU/PRTR, Centro de Investigación y desarrollo Pascual Vila.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring dissolved organic matter (DOM) in surface waters is essential for assessing ecosystem health and detecting pollution. However, conventional spectroscopic techniques often provide limited information about the electrochemical behavior of DOM. This study integrates electrochemical impedance spectroscopy (EIS) with classical methods such as UV–Vis absorption and fluorescence spectroscopies to improve DOM characterization in river water samples. In particular, this coupling provides additional insights into the electrochemical properties of DOM, which are not captured by conventional spectroscopic techniques. This study combined multiple data sources, including physicochemical parameters (e.g., water temperature, pH, conductivity), EIS spectral scores, fluorescence indices, and DOM fractions resolved by multivariate curve resolution–alternating least squares (MCR-ALS) applied to excitation-emission matrix (EEM) fluorescence data. The results from these different methods were then merged into a single dataset for a global principal component analysis (PCA), which allowed us to identify shared patterns and correlations across methods. The results revealed that low-altitude rivers showed the highest DOM content, followed by mid-altitude rivers, while high-altitude rivers presented the lowest. The PCA model indicated that low-frequency regions in the EIS spectra correlated with higher DOM content, whereas mid- to high-frequency regions were associated with lower DOM levels. These frequency-dependent patterns reflected differences in charge transfer and dielectric behavior of DOM in the river samples, which are not accessible through optical techniques. This highlights the potential of EIS as a complementary tool that provides electrochemical information on DOM composition for better water quality assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RiversEnvironmental MonitoringWater Pollutants, ChemicalHumic SubstancesElectrochemical TechniquesSpectrometry, FluorescenceSpectrum AnalysisDielectric Spectroscopy

Stichwörter der Autor:innen

Data integrationElectrochemical impedance spectroscopyFluorescenceMultivariate curve resolutionUV–vis

Substanzen

Water Pollutants, ChemicalHumic Substances

Autor:innen und Institutionen

  • Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, 08034, Barcelona, Spain.
  • Electronic Engineering Department, Polytechnic University of Catalonia (UPC), MNT Group, Jordi Girona 1-3, 08034, Barcelona, Spain.
  • Mathematics Department, Polytechnic University of Catalonia (UPC), Jordi Girona 1-3, 08034, Barcelona, Spain.
  • Department of Environmental Chemistry, IDAEA-CSIC, Jordi Girona 18-26, 08034, Barcelona, Spain. silvia.lacorte@idaea.csic.es.

Förderung

  • Ministerio de Ciencia e Innovación (MCIN) y la Agencia Estatal de Investigación (AEI) and the European Union 'Next Generation EU/PRTR
  • Ministerio de Ciencia e Innovación (MCIN) y la Agencia Estatal de Investigación (AEI) and the European Union ‘Next Generation EU/PRTR
  • Centro de Investigación y desarrollo Pascual Vila

Zitieren

APA

Platikanov, S., Palomas, A., Mata, M. C., Tauler, R., Villar, J., Bragós, R., Bermejo, S., Jaumot, J., & Lacorte, S. (2025). Coupling electrochemical and spectroscopic methods for river water dissolved organic matter characterization. Environmental Monitoring and Assessment. https://doi.org/10.1007/s10661-025-14489-2

Vancouver

Platikanov S, Palomas A, Mata MC, Tauler R, Villar J, Bragós R, et al. Coupling electrochemical and spectroscopic methods for river water dissolved organic matter characterization. Environmental Monitoring and Assessment. 2025. doi:10.1007/s10661-025-14489-2

BibTeX
@article{Platikanov2025,
  author = {Platikanov, Stefan and Palomas, Abel and Mata, Michelle Cedeño and Tauler, Romà and Villar, Jorge and Bragós, Ramon and Bermejo, Sandra and Jaumot, Joaquim and Lacorte, Sílvia},
  title = {Coupling electrochemical and spectroscopic methods for river water dissolved organic matter characterization},
  journal = {Environmental Monitoring and Assessment},
  year = {2025},
  doi = {10.1007/s10661-025-14489-2}
}
Kostenlos starten →