Fachartikel in der Zeitschrift Environmental Monitoring and Assessment, 2024. Verfasst von Maria Fernanda Sobierajski Gisi und 6 weiteren Autor:innen. Beteiligte Einrichtung: The University of Melbourne, School of Agriculture, Food and Ecosystem Sciences (SAFES), Burnley, VIC, Australia. mfsgisi@gmail.com. Hauptthemen laut MEDLINE: Environmental Monitoring, Water Quality, Nephelometry and Turbidimetry, Rivers. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: French National Centre for Scientific Research, France, Melbourne Water.
Abstract (Originalsprache)
This study presents the process of design and development of a low-cost turbidimeter for monitoring water quality, facilitating rigorous spatial-temporal variability analysis within large-scale hydrological systems. We propose a low-cost optical turbidimeter, modifying the existent SEN0189 turbidity sensor, Arduino boards, and additional sensors for temperature compensation. We compared a low-cost system with high-tech sensors, modifying the original low-cost SEN0189 probe for enhanced environmental performance. The three-step methodological framework involved prototype development, compensation for environmental factors, and preparation for future field deployment. Calibration equations with a high coefficient of determination and a temperature correction equation were established. We made adaptations to overcome field deployment challenges, including a 3-D printed sensor case, defining the relationship between measurement uncertainty and energy consumption, and specifying field installation guidelines. In summary, this study presents a comprehensive approach to a low-cost optical turbidity system, demonstrating its potential for accurate and affordable field deployment. We aim to address the critical need for sustainable inland water management tools, making this system a valuable contribution to environmental monitoring practices. We also aim to inspire similar development of open-source monitoring systems within our community.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The University of Melbourne, School of Agriculture, Food and Ecosystem Sciences (SAFES), Burnley, VIC, Australia. mfsgisi@gmail.com.
- UMR 5600 Environnement Ville Et Société, Université Lumière Lyon 2, CNRS, Cedex 08, Lyon, France. mfsgisi@gmail.com.
- UMR 5600 Environnement Ville Et Société, Université Jean Moulin Lyon 3, CNRS, 18 Rue Chevreul Lyon 7, Lyon, France. mfsgisi@gmail.com.
- UMR 5600 Environnement Ville Et Société, Université Lumière Lyon 2, CNRS, Cedex 08, Lyon, France.
- DEEP, INSA Lyon, UR7429, 69621, Villeurbanne, France.
- The University of Melbourne, School of Agriculture, Food and Ecosystem Sciences (SAFES), Burnley, VIC, Australia.
Förderung
- French National Centre for Scientific Research, France
- Melbourne Water
Zitieren
APA
Gisi, M. F. S., Navratil, O., Cherqui, F., Russell, K., Fletcher, T., da Silva, P. V. R. M., & Cossart, E. (2024). From dishwasher to river: how to adapt a low-cost turbidimeter for water quality monitoring. Environmental Monitoring and Assessment. https://doi.org/10.1007/s10661-024-13327-1
Vancouver
Gisi MFS, Navratil O, Cherqui F, Russell K, Fletcher T, da Silva PVRM, et al. From dishwasher to river: how to adapt a low-cost turbidimeter for water quality monitoring. Environmental Monitoring and Assessment. 2024. doi:10.1007/s10661-024-13327-1
BibTeX
@article{Gisi2024,
author = {Gisi, Maria Fernanda Sobierajski and Navratil, Oldrich and Cherqui, Frédéric and Russell, Kathryn and Fletcher, Tim and da Silva, Paulo Vitor Ribeiro Marques and Cossart, Etienne},
title = {From dishwasher to river: how to adapt a low-cost turbidimeter for water quality monitoring},
journal = {Environmental Monitoring and Assessment},
year = {2024},
doi = {10.1007/s10661-024-13327-1}
}
EUVIMED