EUVIMEDEUVIMED entdecken
Crossref

How can contamination be prevented during laboratory analysis of atmospheric samples for microplastics?

Mansoor Ahmad Bhat, Eftade O Gaga, Kadir Gedik

Environmental Monitoring and Assessment · 2024-02 · 196 (2)

DOI: 10.1007/s10661-024-12345-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Monitoring and Assessment, online erschienen am 17.01.2024. Verfasst von Mansoor Ahmad Bhat und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Engineering, Faculty of Engineering, Eskişehir Technical University, 26555, Eskişehir, Türkiye. mansoorahmadbhat@ogr.eski…. Hauptthemen laut MEDLINE: Microplastics, Plastics. Die Arbeit wurde bisher 73-mal zitiert (Crossref) und nennt 68 Literaturangaben. Gefördert von: Eskişehir Teknik Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microplastics (MPs) in the air and indoor environments are of growing concern and have led to increased testing for MPs. This study draws attention to the quality and quantitative measures of MP studies by conducting laboratory experiments (on solutions, filters, and blank samples) that were rarely or were not adopted in the airborne and indoor MP literature. Experiments have been conducted to identify contaminations that may come from experimental procedures while determining MPs in the air samples. MPs in different matrices during experiments were counted and categorized by their shapes. Chemical characterization was performed by Raman Spectroscopy. Results showed that laminar flow is the best option over a fume hood or standard laboratory environment for detecting air MPs to reduce blank levels. Blue-green and Black-Grey were the dominant colors; fiber was the predominant type of MPs seen, and most of them fall under the size range from (1-1000 µm) in different indoor environments and blanks. Common MPs seen were PP, PVA, PTFE, PVC, and HDPE. Thermal treatment of fresh unused filters at 450 °C for 4 h was effective as it reduced the MP count by 50%. Working solutions are mainly contaminated, and their pre-filtration is essential. The average deposition of MPs in blank samples during seven days was around 55 MPs. There is an urgent need for studies on developing quality control and quality assurance of airborne and indoor MPs. Hence, a standard protocol needs to be accepted; by harmonizing procedures, comparable results can be found, uncovering the correct levels of MP contamination, as required for risk assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroplasticsPlasticsEnvironmental MonitoringFiltrationGases

Stichwörter der Autor:innen

Cross-contaminationLaboratory BlanksLaboratory ContaminationMicroplasticsPolymeric ParticlesPrevention Measures

Substanzen

MicroplasticsPlasticsGases

Autor:innen und Institutionen

  • Department of Environmental Engineering, Faculty of Engineering, Eskişehir Technical University, 26555, Eskişehir, Türkiye. mansoorahmadbhat@ogr.eskisehir.edu.tr.
  • Department of Environmental Engineering, Faculty of Engineering, Eskişehir Technical University, 26555, Eskişehir, Türkiye.
  • Environmental Research Center (ÇEVMER), Eskişehir Technical University, 26555, Eskişehir, Türkiye.

Förderung

  • Eskişehir Teknik Üniversitesi

Zitieren

APA

Bhat, M. A., Gaga, E. O., & Gedik, K. (2024). How can contamination be prevented during laboratory analysis of atmospheric samples for microplastics?. Environmental Monitoring and Assessment, 196(2). https://doi.org/10.1007/s10661-024-12345-3

Vancouver

Bhat MA, Gaga EO, Gedik K. How can contamination be prevented during laboratory analysis of atmospheric samples for microplastics?. Environmental Monitoring and Assessment. 2024;196(2). doi:10.1007/s10661-024-12345-3

BibTeX
@article{Bhat2024,
  author = {Bhat, Mansoor Ahmad and Gaga, Eftade O and Gedik, Kadir},
  title = {How can contamination be prevented during laboratory analysis of atmospheric samples for microplastics?},
  journal = {Environmental Monitoring and Assessment},
  year = {2024},
  volume = {196},
  number = {2},
  doi = {10.1007/s10661-024-12345-3}
}
Kostenlos starten →