Novel nontarget LC-HRMS-based approaches for evaluation of drinking water treatment
Environmental Monitoring and Assessment · 2023-06 · 195 (6)
DOI: 10.1007/s10661-023-11348-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Monitoring and Assessment, online erschienen am 26.05.2023. Verfasst von Petra Nováková und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Fisheries and Protection of Waters, South Bohemian Research Centre of Aquaculture and Biodiversity of Hydrocenoses, University of South Bo…. Hauptthemen laut MEDLINE: Drinking Water, Water Pollutants, Chemical, Water Purification, Ozone. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministerstvo Školství, Mládeže a Tělovýchovy, Grantová Agentura České Republiky, University of South Bohemia in České Budějovice.
Abstract (Originalsprache)
A conventional evaluation methodology for drinking water pollution focuses on analysing hundreds of compounds, usually by liquid chromatography–tandem mass spectrometry. High-resolution mass spectrometry allows comprehensive evaluation of all detected signals (compounds) based on their elemental composition, intensity, and numbers. We combined target analysis of 192 emerging micropollutants with nontarget (NT) full-scan/MS/MS methods to describe the impact of treatment steps in detail and assess drinking water treatment efficiency without compound identification. The removal efficiency based on target analytes ranged from − 143 to 97%, depending on the treatment section, technologies, and season. The same effect calculated for all signals detected in raw water by the NT method ranged between 19 and 65%. Ozonation increased the removal of micropollutants from the raw water but simultaneously caused the formation of new compounds. Moreover, ozonation byproducts showed higher persistence than products formed during other types of treatment. We evaluated chlorinated and brominated organics detected by specific isotopic patterns within the developed workflow. These compounds indicated anthropogenic raw water pollution but also potential treatment byproducts. We could match some of these compounds with libraries available in the software. We can conclude that passive sampling combined with nontargeted analysis shows to be a promising approach for water treatment control, especially for long-term monitoring of changes in technology lines because passive sampling dramatically reduces the number of samples and provides time-weighted average information for 2 to 4 weeks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Fisheries and Protection of Waters, South Bohemian Research Centre of Aquaculture and Biodiversity of Hydrocenoses, University of South Bohemia in České Budějovice, Zátiší 728/II, 389 25, Vodňany, Czech Repub…
Förderung
- Ministerstvo Školství, Mládeže a Tělovýchovy
- Grantová Agentura České Republiky
- University of South Bohemia in České Budějovice
Zitieren
APA
Nováková, P., Švecová, H., Bořík, A., & Grabic, R. (2023). Novel nontarget LC-HRMS-based approaches for evaluation of drinking water treatment. Environmental Monitoring and Assessment, 195(6). https://doi.org/10.1007/s10661-023-11348-w
Vancouver
Nováková P, Švecová H, Bořík A, Grabic R. Novel nontarget LC-HRMS-based approaches for evaluation of drinking water treatment. Environmental Monitoring and Assessment. 2023;195(6). doi:10.1007/s10661-023-11348-w
BibTeX
@article{Novkov2023,
author = {Nováková, Petra and Švecová, Helena and Bořík, Adam and Grabic, Roman},
title = {Novel nontarget LC-HRMS-based approaches for evaluation of drinking water treatment},
journal = {Environmental Monitoring and Assessment},
year = {2023},
volume = {195},
number = {6},
doi = {10.1007/s10661-023-11348-w}
}
EUVIMED