Development and optimisation of ex situ portable X-ray fluorescence spectroscopy for heterogenous post-metallurgical sites
Environmental Geochemistry and Health · 2025
DOI: 10.1007/s10653-025-02574-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Geochemistry and Health, 2025. Verfasst von N H Marsay und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Engineering and Applied Sciences, Cranfield University, Cranfield, Bedfordshire, UK. Hauptthemen laut MEDLINE: Spectrometry, X-Ray Emission, Environmental Monitoring, Soil Pollutants, Metals. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Regional Development Fund as part of the Interreg Northwest Europe project.
Abstract (Originalsprache)
Portable X-ray fluorescence spectroscopy (pXRF) is widely used for rapid measurement of metals in soils, however, thorough evaluation of common pre-processing methods and their effectiveness is limited. This study addresses processing methods using samples collected at a highly heterogeneous post-metallurgical site containing, basic oxygen steelmaking (BOS) slag and soil; the former being an important source of potentially toxic and valuable elements. Impact of pre-treatment processes, (sieving, drying, grinding, sample vessel, and ignition) on the accuracy of pXRF measurements was compared against reference ICP-MS measurements.Of the twelve elements detected, four showed qualitative (Cr and Fe r 2 ≥ 0.60, RSD ≤ 30%) or quantitative (Mn and Ca r 2 ≥ 0.70, RSD ≤ 20%) measurements for raw samples. Improving to six elements after pre-processing (Sr qualitative, and Pb, Cr, Mn, Ca, Fe quantitative). Sieving and grinding improved precision (average RSD fell by 7.17 and 8.37% respectively), while drying and grinding enhanced accuracy (average r 2 increased by 0.03 and 0.10 respectively). This study provides the first evidence that organic matter does not significantly impact pXRF accuracy or precision (average r 2 and RSD changed by zero and − 0.32%, respectively). The two distinct matrices (BOS slag and soil) on-site resulted in a bimodal concentration distribution and a negative correlation for Ti. Importantly, this research proposes that not all common pre-processing steps are necessary to generate high-quality data due to their negligible impact on accuracy or precision (such as incineration to remove organic matter), thereby increasing the speed and reducing the cost of data collection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Engineering and Applied Sciences, Cranfield University, Cranfield, Bedfordshire, UK.
- Faculty of Engineering and Applied Sciences, Cranfield University, Cranfield, Bedfordshire, UK. m.d.alamargavidia@cranfield.ac.uk.
Förderung
- European Regional Development Fund as part of the Interreg Northwest Europe project
Zitieren
APA
Marsay, N. H., Wagland, S. T., Campo, P., & Alamar, M. C. (2025). Development and optimisation of ex situ portable X-ray fluorescence spectroscopy for heterogenous post-metallurgical sites. Environmental Geochemistry and Health. https://doi.org/10.1007/s10653-025-02574-x
Vancouver
Marsay NH, Wagland ST, Campo P, Alamar MC. Development and optimisation of ex situ portable X-ray fluorescence spectroscopy for heterogenous post-metallurgical sites. Environmental Geochemistry and Health. 2025. doi:10.1007/s10653-025-02574-x
BibTeX
@article{Marsay2025,
author = {Marsay, N H and Wagland, S T and Campo, P and Alamar, M C},
title = {Development and optimisation of ex situ portable X-ray fluorescence spectroscopy for heterogenous post-metallurgical sites},
journal = {Environmental Geochemistry and Health},
year = {2025},
doi = {10.1007/s10653-025-02574-x}
}
EUVIMED