EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evaluation of a rapid batch export system for electroretinography waveform data

Aomeng Cui, Maria I Nunez, Mia OConnell, Karen M Chen, Stanley Chang, Leejee Suh, Scott E Brodie, Vlad Diaconita

Documenta Ophthalmologica · 19.11.2026

DOI: 10.1007/s10633-026-10162-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Documenta Ophthalmologica, online erschienen am 19.11.2026. Verfasst von Aomeng Cui und 7 weiteren Autor:innen. Beteiligte Einrichtung: Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, 622 W 168th Street, Presbyterian Hospital Building, 18thFloor,…. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS, National Eye Institute, Research to Prevent Blindness.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Accurate application of electroretinography (ERG) remains challenging due to the heterogeneity of retinal disorders. Despite its potential as a diagnostic tool, the clinical use of ERG is limited by the expertise required for interpretation and the error-prone manual extraction of waveform data. At scale, waveform analysis in academic research and clinical trials is made difficult by these challenges. This study performed external validation and quality assessment of automated compared to manual extraction and collection of raw ERG waveforms. METHODS: Raw waveform data was collected using International Society for Clinical Electrophysiology of Vision (ISCEV) standard ERG studies from the ophthalmology practice at Columbia University. A recently developed automated batch exporting tool (Espion, Diagnosys LLC, Lowell, MA) was used to retrieve and compile data and compare with manually collected data for 357 patient sessions. RESULTS: The automated and manually exported data had 99.75% ± 0.17% similarity using a Jaccard similarity test, suggesting the automated tool is both rapid and highly accurate. We identified several inconsistencies leading to errors in the automated batch export. The most common errors in compiled batch exported data included: improperly merging two ERG files taken on the same day and lack of accounting for missing data. CONCLUSIONS: Use of batch export with manual oversight for sources of potential error can allow for faster, more effective data gathering and analysis of large-scale ERG waveform datasets in academic and clinical trial settings.

Schlagwörter

Stichwörter der Autor:innen

Batch exportERGISCEVQuality assessment

Autor:innen und Institutionen

  • Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, 622 W 168th Street, Presbyterian Hospital Building, 18thFloor, New York, NY, 10032, USA.
  • Department of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA.
  • Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, 622 W 168th Street, Presbyterian Hospital Building, 18thFloor, New York, NY, 10032, USA. vd2374@cumc.columbia.edu.
  • Department of Ophthalmology, Columbia University Irving Medical Center, New York, NY, USA. vd2374@cumc.columbia.edu.

Förderung

  • NEI NIH HHS
  • National Eye Institute
  • Research to Prevent Blindness

Zitieren

APA

Cui, A., Nunez, M. I., OConnell, M., Chen, K. M., Chang, S., Suh, L., Brodie, S. E., & Diaconita, V. (2026). Evaluation of a rapid batch export system for electroretinography waveform data. Documenta Ophthalmologica. https://doi.org/10.1007/s10633-026-10162-2

Vancouver

Cui A, Nunez MI, OConnell M, Chen KM, Chang S, Suh L, et al. Evaluation of a rapid batch export system for electroretinography waveform data. Documenta Ophthalmologica. 2026. doi:10.1007/s10633-026-10162-2

BibTeX
@article{Cui2026,
  author = {Cui, Aomeng and Nunez, Maria I and OConnell, Mia and Chen, Karen M and Chang, Stanley and Suh, Leejee and Brodie, Scott E and Diaconita, Vlad},
  title = {Evaluation of a rapid batch export system for electroretinography waveform data},
  journal = {Documenta Ophthalmologica},
  year = {2026},
  doi = {10.1007/s10633-026-10162-2}
}
Kostenlos starten →