Association between dynamic pupil parameters and corneal sub-basal nerve plexus morphology
Documenta Ophthalmologica · 27.06.2026
DOI: 10.1007/s10633-026-10126-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Documenta Ophthalmologica, online erschienen am 27.06.2026. Verfasst von Wenyan Zhou und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Peking University First Hospital, Beijing, China. Die Arbeit nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Beijing Municipality, National High Level Hospital Clinical Research Funding.
Abstract (Originalsprache)
Purpose
To evaluate the association between dynamic pupillometry parameters and in vivo confocal microscopy (IVCM)-derived corneal sub-basal nerve morphology in patients with immune-related dry eye disease.
Methods
A cross-sectional study was conducted on 28 patients with immune-related dry eye disease (DED). Corneal sub-basal nerve morphology, including corneal nerve fiber length density (CNFL), intensity, and tortuosity, was quantified using IVCM. Dynamic pupillary light reflexes, including pupil size diameter and constriction/dilation velocities, were measured via automated pupillometry. Correlation and multivariate regression analysis were employed to determine the independent associations between structural nerve metrics and functional pupillary parameters.
Results
Significant positive correlations were observed between CNFL and baseline pupil size, recovery pupil size, and total contraction and dilation time. Multivariate regression confirmed that CNFL remained an independent predictor of baseline pupil diameter after adjusting for age and gender.
Conclusion
Structural rarefaction of the corneal sub-basal nerves is closely mirrored by functional impairments in pupillary dynamics. Dynamic pupillometry may provide complementary functional information associated with corneal nerve alterations in patients with immune-related DED.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Peking University First Hospital, Beijing, China.
- Department of Ophthalmology, the First Affiliated Hospital of Zhejiang University, Hangzhou, Zhejiang, China.
- Department of Ultrasound, Peking University First Hospital, Beijing, China.
- Department of Rheumatology and Immunology, Peking University Third Hospital, Beijing, China.
- Department of Ophthalmology, Peking University First Hospital, Beijing, China. fengyun@bjmu.edu.cn.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Beijing Municipality
- National High Level Hospital Clinical Research Funding
Zitieren
APA
Zhou, W., Zhang, Z., Yu, H., Li, J., Li, R., Yao, Z., He, X., & Feng, Y. (2026). Association between dynamic pupil parameters and corneal sub-basal nerve plexus morphology. Documenta Ophthalmologica. https://doi.org/10.1007/s10633-026-10126-6
Vancouver
Zhou W, Zhang Z, Yu H, Li J, Li R, Yao Z, et al. Association between dynamic pupil parameters and corneal sub-basal nerve plexus morphology. Documenta Ophthalmologica. 2026. doi:10.1007/s10633-026-10126-6
BibTeX
@article{Zhou2026,
author = {Zhou, Wenyan and Zhang, Zhiyu and Yu, Haozhe and Li, Jingyi and Li, Renxu and Yao, Zhongqiang and He, Xiaojun and Feng, Yun},
title = {Association between dynamic pupil parameters and corneal sub-basal nerve plexus morphology},
journal = {Documenta Ophthalmologica},
year = {2026},
doi = {10.1007/s10633-026-10126-6}
}
EUVIMED