EUVIMEDEUVIMED entdecken
Crossref

Short-term variability of the multifocal ERG in clinical settings

Sunny Kahlon, Dominique Ebedes, Radouil Tzekov

Documenta Ophthalmologica · 2026

DOI: 10.1007/s10633-025-10069-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Documenta Ophthalmologica, 2026. Verfasst von Sunny Kahlon und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University of South Florida, Tampa, FL, USA. sk35@usf.edu. Hauptthemen laut MEDLINE: Electroretinography, Retina. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to evaluate the effect of repeat testing on N1 and P1 amplitudes, signal-to-noise (SNR) ratios, and amplitude ring ratios (RR) in multifocal electroretinography (mfERG). METHODS: This was a retrospective review of mfERG records from 08/2022 to 05/2023. Patients were tested binocularly with the Espion system (Diagnosys LLC). Only records from patients with repeat mfERG tests at the same appointment were included. N1 and P1 amplitudes, signal-to-noise ratio (SNR), and amplitude ring ratios were evaluated for the first recording (run #1), the second recording (run #2), and the combination of run #1 and run #2 (combined run). RESULTS: Data was collected for 93 eyes from 47 patients (5 males, 42 females) with a mean patient age of 56.1 ± 17.3 years. No change was observed between run #1 and run #2 for N1 or P1 amplitudes, however amplitudes of the combined run decreased significantly (p < 0.05) compared to run #1 amplitudes for all rings, right and left eyes (except for ring 1 in right eyes). SNR increased significantly from run #1 to run #2 for rings 2-5 (~10%), but not for ring 1. The number of blinks recorded during testing decreased from run #1 to run #2 (p < 0.001). Amplitude ring ratios R5/R4 and R5/R3 did not change significantly from run #1 to run #2, while amplitude R1/R2 ratio decreased significantly (p < 0.05). CONCLUSION: The change in signal quality from run #1 to run #2 suggests a superior quality signal in the second run. Furthermore, the decreased P1 amplitude in the combined run compared to run #1 should be considered when a clinician uses the combined run for their final report.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroretinographyRetinaHumansMaleRetrospective StudiesFemaleMiddle AgedAdultSignal-To-Noise RatioAgedReproducibility of Results

Stichwörter der Autor:innen

HydroxychloroquineKeywords Multifocal ERGMaculopathyRing ratios

Autor:innen und Institutionen

  • Department of Ophthalmology, University of South Florida, Tampa, FL, USA. sk35@usf.edu.
  • Department of Ophthalmology, University of South Florida, Tampa, FL, USA.

Zitieren

APA

Kahlon, S., Ebedes, D., & Tzekov, R. (2026). Short-term variability of the multifocal ERG in clinical settings. Documenta Ophthalmologica. https://doi.org/10.1007/s10633-025-10069-4

Vancouver

Kahlon S, Ebedes D, Tzekov R. Short-term variability of the multifocal ERG in clinical settings. Documenta Ophthalmologica. 2026. doi:10.1007/s10633-025-10069-4

BibTeX
@article{Kahlon2026,
  author = {Kahlon, Sunny and Ebedes, Dominique and Tzekov, Radouil},
  title = {Short-term variability of the multifocal ERG in clinical settings},
  journal = {Documenta Ophthalmologica},
  year = {2026},
  doi = {10.1007/s10633-025-10069-4}
}
Kostenlos starten →