EUS-Guided Shear Wave Elastography in a Real-World Cohort: Diagnostic Accuracy and the Impact of Measurement Variability
Digestive Diseases and Sciences · 2026
DOI: 10.1007/s10620-026-10139-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Digestive Diseases and Sciences, 2026. Verfasst von Umang Arora und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Institute of Liver Gastroenterology and Pancreatic Sciences (ILGPS), Sir Ganga Ram Hospital, New Delhi, India. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver Cirrhosis, Endosonography, Liver. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Liver stiffness measurement (LSM) is a non-invasive surrogate for hepatic fibrosis that informs risk stratification and management. Vibration-controlled transient elastography (VCTE; FibroScan®) is well established. Endoscopic ultrasound-guided shear wave elastography (EUS-SWE) offers the potential to assess LSM during routine EUS; however, its diagnostic performance remains uncertain. METHODS: In this prospective, single-center diagnostic accuracy study, consecutive adults without biliary obstruction who were undergoing EUS additionally underwent LSM measurement from the right hepatic lobe using EUS-SWE (Olympus ME3) and same-day VCTE. VCTE thresholds defined advanced chronic liver disease (ACLD; > 15 kPa), cirrhosis (> 12 kPa), and advanced fibrosis (> 8 kPa). EUS-SWE performance was evaluated using correlation, Bland-Altman agreement, and area under the receiver-operating characteristic curve (AUROC). RESULTS: Among 146 patients (median VCTE-LSM 6.05 kPa, range 3-53.3), 57, 41, and 31 had LSM ≥ 8, ≥ 12, and ≥ 15 kPa, respectively. EUS-SWE showed moderate correlation with VCTE (Spearman ρ = 0.65, p < 0.001) and reported higher values by 34.1% (95% limits of agreement:-64.8% to 133.1%) without proportional bias on Bland-Altman analysis. EUS-SWE showed excellent accuracy for screening relevant VCTE-LSM thresholds with AUROC (95% CI) 0.89 (0.81-0.97) for ACLD, 0.89 (0.82-0.96) for cirrhosis, and 0.85 (0.79-0.92) for advanced fibrosis. Optimal EUS-SWE threshold for VCTE-defined ACLD was 12.9 kPa (sensitivity 93%, specificity 77%), representing the optimal screening cutoff; a regression-derived threshold of 21.4 kPa (sensitivity 67%, specificity 93%) represents the mathematical equivalent EUS-SWE value to VCTE ≥ 15 kPa, appropriate for direct modality comparison. Accuracy for ACLD declined monotonously with increasing variability (IQR/LSM%): AUROC 0.97 (for < 30%), 0.86 (30-45%), 0.83 (45-60%), and 0.78 (≥ 60%). CONCLUSION: EUS-SWE yields LSM values approximately 34% higher than VCTE-LSM; the two modalities are not interchangeable and require modality-specific thresholds. EUS-SWE provides accurate prediction of VCTE-defined fibrosis thresholds, particularly when IQR/LSM% ≤ 45%, and represents a promising adjunct for opportunistic liver stiffness assessment during routine EUS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Institute of Liver Gastroenterology and Pancreatic Sciences (ILGPS), Sir Ganga Ram Hospital, New Delhi, India.
- Department of Gastroenterology, Institute of Liver Gastroenterology and Pancreatic Sciences (ILGPS), Sir Ganga Ram Hospital, New Delhi, India. dranilarora50@gmail.com.
Zitieren
APA
Arora, U., Khare, S., Anikhindi, S., Khandelwal, A., Rana, R., Kumar, A., Sharma, P., Bansal, N., Sachdeva, M., Ranjan, P., Kumar, M., & Arora, A. (2026). EUS-Guided Shear Wave Elastography in a Real-World Cohort: Diagnostic Accuracy and the Impact of Measurement Variability. Digestive Diseases and Sciences. https://doi.org/10.1007/s10620-026-10139-w
Vancouver
Arora U, Khare S, Anikhindi S, Khandelwal A, Rana R, Kumar A, et al. EUS-Guided Shear Wave Elastography in a Real-World Cohort: Diagnostic Accuracy and the Impact of Measurement Variability. Digestive Diseases and Sciences. 2026. doi:10.1007/s10620-026-10139-w
BibTeX
@article{Arora2026,
author = {Arora, Umang and Khare, Shivam and Anikhindi, Shrihari and Khandelwal, Ashiesh and Rana, Randeep and Kumar, Ashish and Sharma, Praveen and Bansal, Naresh and Sachdeva, Munish and Ranjan, Piyush and Kumar, Mandhir and Arora, Anil},
title = {EUS-Guided Shear Wave Elastography in a Real-World Cohort: Diagnostic Accuracy and the Impact of Measurement Variability},
journal = {Digestive Diseases and Sciences},
year = {2026},
doi = {10.1007/s10620-026-10139-w}
}
EUVIMED