EUVIMEDEUVIMED entdecken
Multizentrische Studie

Evaluation of Self-Expandable Metallic Stent Characteristics Associated with Longer Patency in Patients with Unresectable Malignant Distal Biliary Obstruction: A Multicenter Retrospective Study

Mitsuru Okuno, Tsuyoshi Mukai, Fumiya Kataoka, Keisuke Iwata, Ryuichi Tezuka, Yuhei Iwasa, Takuya Koizumi, Kota Shimojo, Yosuke Ohashi, Shota Iwata, Naoki Mita, Akinori Maruta und 8 weitere

Digestive Diseases and Sciences · 2026

DOI: 10.1007/s10620-026-09908-4 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Digestive Diseases and Sciences, 2026. Verfasst von Mitsuru Okuno und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Matsunami General Hospital, Dendai 185-1, Kasamatsu-Cho, Hashima-Gun, Gifu, 501-6062, Japan. mokuno-gif@umin.ac.jp. Hauptthemen laut MEDLINE: Self Expandable Metallic Stents, Cholestasis. Die Arbeit nennt 22 Literaturangaben. Gefördert von: JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND AIMS: Various self-expandable metallic stents (SEMS) have been developed to improve the patency of patients with malignant distal biliary obstruction (MDBO). This retrospective study aimed to evaluate SEMS characteristics associated with longer patency in initial SEMS placement for unresectable MDBO. METHODS: Patients with unresectable MDBO identified in databases from four medical centers were analyzed. Patient background, SEMS type, and time to recurrent biliary obstruction (TRBO) were analyzed. The extracted variables were subjected to propensity score matching (PSM) to reduce selection bias. RESULTS: Between 2010 and 2025, 780 patients with MDBO were identified, 501 of whom met the inclusion criteria. In the multivariate analysis, 12-mm bore size, laser-cut SEMS, and 8-cm length SEMS were identified as independent significant factors contributing to TRBO. To confirm the utility of three significant factors, PSM analysis was performed on each. A total of 126 patients with 12- and 10-mm bore-size SEMS, 34 patients with laser-cut and braided SEMS, and 169 patients with 8-cm and < 8-cm length SEMS were compared. The hazard ratio of the 12-mm bore size SEMS was 0.65 (95% CI 0.44-0.98, P = 0.037), laser-cut SEMS was 0.24 (95% CI 0.07-0.86, P = 0.029), and SEMS < 8-cm length was 0.68 (95% CI 0.47-0.99, P = 0.044). The stent occlusion rate was lower in the 12-mm SEMS group (16%) than in the 10-mm SEMS group (26%). No stent migration was observed in laser-cut SEMS. CONCLUSIONS: Because the choice of SEMS length depends on the patient's condition, a 12-mm bore size and laser-cut SEMS seem promising for SEMS selection. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov UMIN000058935.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Self Expandable Metallic StentsCholestasisHumansRetrospective StudiesFemaleAgedMaleMiddle AgedProsthesis DesignTreatment OutcomeAged, 80 and over

Stichwörter der Autor:innen

12-mm bore sizeLaser cutLonger stent patencyPropensity score matchingSelf-expandable metallic stent

Autor:innen und Institutionen

  • Department of Gastroenterology, Matsunami General Hospital, Dendai 185-1, Kasamatsu-Cho, Hashima-Gun, Gifu, 501-6062, Japan. mokuno-gif@umin.ac.jp.
  • Department of Gastroenterology, Matsunami General Hospital, Dendai 185-1, Kasamatsu-Cho, Hashima-Gun, Gifu, 501-6062, Japan.
  • Department of Gastroenterology, Gifu Municipal Hospital, Gifu, Japan.
  • First Department of Internal Medicine, Gifu University Hospital, Gifu, Japan.
  • Department of Gastroenterology, Gifu Prefecture General Medical Center, Gifu, Japan.
  • Department of Medicine, Division of Gastroenterology, Shiga University of Medical Science, Otsu, Japan.

Förderung

  • JSPS KAKENHI

Zitieren

APA

Okuno, M., Mukai, T., Kataoka, F., Iwata, K., Tezuka, R., Iwasa, Y., Koizumi, T., Shimojo, K., Ohashi, Y., Iwata, S., Mita, N., Maruta, A., Uemura, S., Ichikawa, H., Yoshida, K., Iwashita, T., Tomita, E., Yasuda, I., Moriwaki, H., & Shimizu, M. (2026). Evaluation of Self-Expandable Metallic Stent Characteristics Associated with Longer Patency in Patients with Unresectable Malignant Distal Biliary Obstruction: A Multicenter Retrospective Study. Digestive Diseases and Sciences. https://doi.org/10.1007/s10620-026-09908-4

Vancouver

Okuno M, Mukai T, Kataoka F, Iwata K, Tezuka R, Iwasa Y, et al. Evaluation of Self-Expandable Metallic Stent Characteristics Associated with Longer Patency in Patients with Unresectable Malignant Distal Biliary Obstruction: A Multicenter Retrospective Study. Digestive Diseases and Sciences. 2026. doi:10.1007/s10620-026-09908-4

BibTeX
@article{Okuno2026,
  author = {Okuno, Mitsuru and Mukai, Tsuyoshi and Kataoka, Fumiya and Iwata, Keisuke and Tezuka, Ryuichi and Iwasa, Yuhei and Koizumi, Takuya and Shimojo, Kota and Ohashi, Yosuke and Iwata, Shota and Mita, Naoki and Maruta, Akinori and Uemura, Shinya and Ichikawa, Hironao and Yoshida, Kensaku and Iwashita, Takuji and Tomita, Eiichi and Yasuda, Ichiro and Moriwaki, Hisataka and Shimizu, Masahito},
  title = {Evaluation of Self-Expandable Metallic Stent Characteristics Associated with Longer Patency in Patients with Unresectable Malignant Distal Biliary Obstruction: A Multicenter Retrospective Study},
  journal = {Digestive Diseases and Sciences},
  year = {2026},
  doi = {10.1007/s10620-026-09908-4}
}
Kostenlos starten →