Vergleichsstudie in der Zeitschrift Cardiovascular Drugs and Therapy, 2025. Verfasst von Zhiqiang Ma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Departments of Internal Medicine, Liyuan Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuh…. Hauptthemen laut MEDLINE: Angioplasty, Balloon, Coronary, Cardiac Catheters, Coated Materials, Biocompatible, Coronary Artery Disease. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Although a number of studies involving small-vessel de novo coronary disease showed clinical benefits of drug-coated balloons (DCB), the role of DCB in large vessel lesions is still unclear.
Methods
We searched main electronic databases for randomized controlled trials (RCTs) comparing DCB with stents for large vessel de novo coronary artery disease. The primary endpoint was major cardiovascular adverse events (MACE), composite cardiovascular death (CD), myocardial infarction (MI), or target lesion revascularization (TLR).
Results
This study included 7 RCTs with 770 participants. DCB were associated with a marked risk reduction in MACE [Risk Ratio (RR): 0.48; 95% confidence interval [CI]: 0.24 to 0.97; P = 0.04], TLR (RR: 0.53; 95% CI: 0.25 to 1.14; P = 0.10), and late lumen loss [standard mean difference (SMD): -0.57; 95% CI: -1.09 to -0.05; P = 0.03] as compared with stents. There is no significant difference in MI (RR: 0.58; 95% CI: 0.21 to 1.54; P = 0.27), CD (RR: 0.33; 95% CI: 0.06 to 1.78; P = 0.19), and minimal lumen diameter (SMD: -0.34; 95% CI: -0.72 to 0.05; P = 0.08) between groups. In subgroup analyses, the risk reduction of MACE persisted in patients with chronic coronary syndrome (RR: 0.25; 95% CI: 0.07 to 0.89; P = 0.03), and patients receiving DCB vs. bare metal stent (RR: 0.19; 95% CI: 0.05 to 0.73; P = 0.01). In addition, there was no significant difference between the DCB group and the drug eluting stent group for MACE (RR: 0.69; 95% CI: 0.30 to 1.60; P = 0.38).
Conclusion
DCB may be an effective therapeutic option in patients with large vessel de novo coronary artery disease.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Cardiology, Departments of Internal Medicine, Liyuan Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430000, People's Republic of China.
- Division of Cardiology, Departments of Internal Medicine, Liyuan Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430000, People's Republic of China. zhengyili_hy@sina.com.
ORCID-Profile: Zhengyi Li
Zitieren
APA
Ma, Z., Liu, K., Hu, Y., Hu, X., Wang, B., & Li, Z. (2025). Comparison Between Drug-Coated Balloon and Stents in Large De Novo Coronary Artery Disease: A Systematic Review and Meta-Analysis of RCT Data. Cardiovascular Drugs and Therapy. https://doi.org/10.1007/s10557-024-07548-2
Vancouver
Ma Z, Liu K, Hu Y, Hu X, Wang B, Li Z. Comparison Between Drug-Coated Balloon and Stents in Large De Novo Coronary Artery Disease: A Systematic Review and Meta-Analysis of RCT Data. Cardiovascular Drugs and Therapy. 2025. doi:10.1007/s10557-024-07548-2
BibTeX
@article{Ma2025,
author = {Ma, Zhiqiang and Liu, Kanling and Hu, Yanhui and Hu, Xiwen and Wang, Binyu and Li, Zhengyi},
title = {Comparison Between Drug-Coated Balloon and Stents in Large De Novo Coronary Artery Disease: A Systematic Review and Meta-Analysis of RCT Data},
journal = {Cardiovascular Drugs and Therapy},
year = {2025},
doi = {10.1007/s10557-024-07548-2}
}
EUVIMED