Feasibility and agreement study of a handheld ultrasound device with continuous-wave doppler in transcatheter aortic valve implantation patients

Adrián Margarida de Castro, Jon Zubiaur, Raquel Pérez-Barquín, Manuel Lozano González, Gonzalo Martín Gorría, Luis Javier Ruíz Guerrero, Andrea Teira Calderón, David Serrano Lozano, Gabriela Veiga Fernández, Elton Carreiro Da Cunha, Nuria Gutiérrez Ruiz, Francisco González-Vílchez und 1 weitere

The International Journal of Cardiovascular Imaging · 2026

DOI: 10.1007/s10554-026-03622-y ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2026. Verfasst von Adrián Margarida de Castro und 12 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Universitario Marqués de Valdecilla, IDIVAL, University of Cantabria, Santander, Spain. Hauptthemen laut MEDLINE: Aortic Valve, Aortic Valve Stenosis, Echocardiography, Doppler, Transcatheter Aortic Valve Replacement. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Instituto de Investigación Sanitaria, IDIVAL.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The use of hand-held ultrasound devices (HHUD) is expanding in clinical practice, yet there is limited evidence regarding their role in evaluating transcatheter aortic valve implantation (TAVI). This study assessed the concordance between measurements obtained using an HHUD with continuous wave Doppler (CW) capability and a reference ultrasound system in patients with TAVI prostheses. A prospective, single-centre observational study was conducted in patients with TAVI prostheses. Following a reference echocardiogram by an expert operator, a second blinded evaluation was performed using a HHUD (Kosmos™, EchoNous) with CW Doppler by an intermediate-experience operator. Key valvular parameters were assessed with CW Doppler, and concordance with the reference was evaluated using intraclass correlation coefficient (ICC), linear regression, and Bland-Altman analysis. A total of 64 patients were included after excluding 3 (4.5%) due to measurement difficulties with the HHUD. The mean age was 81 years, with 35.9% being female. Balloon-expandable TAVI accounted for 79,7% of cases, while 20,3% were self-expanding. The HHUD showed good-to-excellent agreement with the reference TTE in the main 4 parameters of valve function: Mean transvalvular gradient (ICC = 0.76), maximum aortic velocity (ICC = 0.83), transvalvular velocity time integral (VTI) (ICC = 0.87) and left ventricle outflow tract VTI (ICC = 0.8). The agreement was good in the remaining echocardiographic measurements. A HHUD with continuous wave Doppler capability showed good concordance with standard echocardiography in patients with TAVI, even when used by operators with intermediate experience.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic ValveAortic Valve StenosisEchocardiography, DopplerTranscatheter Aortic Valve ReplacementHumansFemaleAged, 80 and overProspective StudiesPredictive Value of TestsFeasibility StudiesReproducibility of ResultsMaleAgedHeart Valve ProsthesisProsthesis DesignTreatment OutcomeEquipment DesignObserver Variation

Stichwörter der Autor:innen

Continuous wave dopplerEchocardiographyHandheld ultrasound deviceProsthetic valve assessmentTranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Hospital Universitario Marqués de Valdecilla, IDIVAL, University of Cantabria, Santander, Spain.
  • Cardiology, Hospital Universitario Clínico Valladolid, Valladolid, Spain.
  • Cardiology, Hospital Universitario Marqués de Valdecilla, IDIVAL, University of Cantabria, Santander, Spain.
  • Hospital Universitario Marqués de Valdecilla, IDIVAL, University of Cantabria, Santander, Spain. jonzubiaur5@gmail.com.
  • Cardiology, Hospital Universitario Marqués de Valdecilla, IDIVAL, University of Cantabria, Santander, Spain. jonzubiaur5@gmail.com.
  • Cardiology, Hospital Universitario La Paz, Madrid, Spain. jonzubiaur5@gmail.com.

Förderung

  • Instituto de Investigación Sanitaria, IDIVAL

Zitieren

APA

Margarida de Castro, A., Zubiaur, J., Pérez-Barquín, R., Lozano González, M., Martín Gorría, G., Ruíz Guerrero, L. J., Teira Calderón, A., Serrano Lozano, D., Veiga Fernández, G., Carreiro Da Cunha, E., Gutiérrez Ruiz, N., González-Vílchez, F., & Vázquez de Prada Tiffe, J. A. (2026). Feasibility and agreement study of a handheld ultrasound device with continuous-wave doppler in transcatheter aortic valve implantation patients. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-026-03622-y

Vancouver

Margarida de Castro A, Zubiaur J, Pérez-Barquín R, Lozano González M, Martín Gorría G, Ruíz Guerrero LJ, et al. Feasibility and agreement study of a handheld ultrasound device with continuous-wave doppler in transcatheter aortic valve implantation patients. The International Journal of Cardiovascular Imaging. 2026. doi:10.1007/s10554-026-03622-y

BibTeX
@article{MargaridadeCastro2026,
  author = {Margarida de Castro, Adrián and Zubiaur, Jon and Pérez-Barquín, Raquel and Lozano González, Manuel and Martín Gorría, Gonzalo and Ruíz Guerrero, Luis Javier and Teira Calderón, Andrea and Serrano Lozano, David and Veiga Fernández, Gabriela and Carreiro Da Cunha, Elton and Gutiérrez Ruiz, Nuria and González-Vílchez, Francisco and Vázquez de Prada Tiffe, José Antonio},
  title = {Feasibility and agreement study of a handheld ultrasound device with continuous-wave doppler in transcatheter aortic valve implantation patients},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2026},
  doi = {10.1007/s10554-026-03622-y}
}
Kostenlos starten →