EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clockwise aortic root rotation in patients with tetralogy of fallot assessed with cardiovascular magnetic resonance imaging

Marco Voortman, Jan van Es, Clemens von Birgelen, Eline H Ploumen, Carine J M Doggen, Lodewijk J Wagenaar

The International Journal of Cardiovascular Imaging · 2025

DOI: 10.1007/s10554-025-03438-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Cardiovascular Imaging, 2025. Verfasst von Marco Voortman und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, Enschede, 7512 KZ, The Netherlands. Hauptthemen laut MEDLINE: Tetralogy of Fallot, Magnetic Resonance Imaging, Cine, Aorta, Aortic Valve. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rotation of the aortic root (AoR) has previously been observed in children with Tetralogy of Fallot (TOF) using 2-dimensional echocardiography. The present study uses cardiovascular magnetic resonance (CMR) imaging to assess whether a clockwise AoR rotation is a common feature in adults with TOF. AoR rotation was measured in the CMR images of consecutive adult patients with corrected TOF and controls. The AoR rotation was assessed in the parasternal short-axis view by measuring the angle of the non-coronary sinus (angle NCS) relative to the interatrial septum (IAS). The angle between IAS and posterior atrial wall was measured to asses IAS reliability as a key anatomical landmark. Inter-observer agreement was determined using intra-class correlation coefficients (ICC). A total of 25 adults with TOF (mean age:33.2 ± 13.1 years;52% male) and 30 controls (mean age:54.5 ± 19.0 years;50% male) were assessed. The angle NCS was greater in TOF patients than in controls (46.2 ± 17.1⁰vs.23.4 ± 15.0⁰, p < 0.001), reflecting a clockwise AoR rotation. As expected, between TOF patients and controls there was no significant difference in the angle IAS (81.1 ± 8.4⁰vs.78.4 ± 9.5⁰, p = 0.46). Inter-observer reliability of CMR measurements was good for the clinically important angle NCS (ICC 0.77, 95%-CI:0.63–0.86) and moderate for the angle IAS (ICC 0.68, 95%-CI:0.51–0.80). This is the first study to demonstrate with CMR that a clockwise rotation of the AoR is a common feature in patients with TOF. This clinical investigation shows the value of CMR for the assessment of the spatial AoR position in adult patients with congenital heart disease.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tetralogy of FallotMagnetic Resonance Imaging, CineAortaAortic ValveHumansMaleFemaleAdultPredictive Value of TestsReproducibility of ResultsMiddle AgedCase-Control StudiesObserver VariationRotationYoung AdultAnatomic LandmarksAged

Stichwörter der Autor:innen

Aortic rootMagnetic resonance imagingTetralogy of fallot

Autor:innen und Institutionen

  • Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, Enschede, 7512 KZ, The Netherlands.
  • Department of Health Technology and Services Research, Faculty of Behavioural Management and Social Sciences, Technical Medical Centre, University of Twente, Enschede, The Netherlands.
  • Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Koningsplein 1, Enschede, 7512 KZ, The Netherlands. l.wagenaar@mst.nl.

Zitieren

APA

Voortman, M., van Es, J., von Birgelen, C., Ploumen, E. H., Doggen, C. J. M., & Wagenaar, L. J. (2025). Clockwise aortic root rotation in patients with tetralogy of fallot assessed with cardiovascular magnetic resonance imaging. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-025-03438-2

Vancouver

Voortman M, van Es J, von Birgelen C, Ploumen EH, Doggen CJM, Wagenaar LJ. Clockwise aortic root rotation in patients with tetralogy of fallot assessed with cardiovascular magnetic resonance imaging. The International Journal of Cardiovascular Imaging. 2025. doi:10.1007/s10554-025-03438-2

BibTeX
@article{Voortman2025,
  author = {Voortman, Marco and van Es, Jan and von Birgelen, Clemens and Ploumen, Eline H and Doggen, Carine J M and Wagenaar, Lodewijk J},
  title = {Clockwise aortic root rotation in patients with tetralogy of fallot assessed with cardiovascular magnetic resonance imaging},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2025},
  doi = {10.1007/s10554-025-03438-2}
}
Kostenlos starten →