EUVIMEDEUVIMED entdecken
Vergleichsstudie

Performance of respiratory gated 4D flow MRI with adaptive k-space reordering in healthy controls and aortic dissection: reproducibility and agreement with 2D phase contrast MRI

Qingdi Wang, Xiaojing Guo, Emma Hornsey, Lucy McKenna, Leonid Churilov, Mark Brooks, George Matalanis, Jason Chuen, Eric Poon, Daniel Staeb, Ning Jin, Andrew Ooi und 1 weitere

The International Journal of Cardiovascular Imaging · 2024

DOI: 10.1007/s10554-024-03298-2 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Qingdi Wang und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia. qingdiw@student.…. Hauptthemen laut MEDLINE: Aortic Dissection, Aortic Aneurysm, Thoracic, Hemodynamics, Aorta, Thoracic. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Royal Australian and New Zealand College of Radiologists.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A four-dimensional phase-contrast magnetic resonance imaging sequence with respiratory-controlled adaptive k-space reordering (ReCAR-4DPC) offers potential benefits of improved scan efficiency and motion robustness. The purpose of this study was to evaluate the reproducibility of flow measurement using this technique and to compare hemodynamic metrics obtained to two-dimensional phase contrast MRI (2DPC)-derived metrics of the thoracic aorta. ReCAR-4DPC was performed with identical scan parameters in 15 healthy volunteers (6M,9F, mean [range] 37 [23-47] years) and 11 patients with thoracic aortic dissection (6M,5F, 56 [31-81] years) and acquisition time was recorded. Peak systolic velocity (PSV), average flow (AF) and net forward volume (NFV) were quantified by two readers for ReCAR-4DPC at ascending, descending and diaphragmatic aorta levels. Reference standard 2DPC measurements at the same levels were performed by a separate experienced cardiovascular radiologist. ReCAR-4DPC intra-reader agreement, inter-reader agreement, inter-scan repeatability and concordance with 2DPC-derived metrics (all segments combined) were evaluated with Lin's concordance correlation coefficient (LCCC) and reduced major axis regression. The overall average ± SD MRI acquisition time of all subjects was 11:59 ± 3:57 min, with shorter average times (9:37 ± 1:57 min) in healthy volunteers compared to patients (15:13 ± 3:44 min). There was near-perfect intra-reader, inter-reader and inter-scan concordance (LCCC for all metrics > 0.97, > 0.98 and > 0.92 respectively) for ReCAR-4DPC. Concordance with 2DPC was also high (LCCC all > 0.89), with overall minimally lower PSV, AF and NFV values derived from ReCAR-4DPC compared to reference 2DPC derived metrics. ReCAR-4DPC is a reproducible and relatively fast approach for comprehensive measurement of thoracic aortic flow metrics, with robust correlation to conventional 2DPC.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic DissectionAortic Aneurysm, ThoracicHemodynamicsAorta, ThoracicRespiratory-Gated Imaging TechniquesImage Interpretation, Computer-AssistedMagnetic Resonance AngiographyMagnetic Resonance ImagingPerfusion ImagingHumansReproducibility of ResultsMaleMiddle AgedFemalePredictive Value of TestsAdultBlood Flow VelocityAgedObserver VariationYoung AdultCase-Control StudiesAged, 80 and overRegional Blood Flow

Stichwörter der Autor:innen

4D flowAortaCardiovascularReproducibility of resultsRespiratory-gated imaging techniques

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia. qingdiw@student.unimelb.edu.au.
  • Department of Mechanical Engineering, Melbourne School of Engineering, The University of Melbourne, Melbourne, VIC, 3010, Australia.
  • Department of Radiology, Austin Health, Heidelberg, VIC, 3084, Australia.
  • Department of Medicine, Melbourne Medical School, Royal Melbourne Hospital, The University of Melbourne, Heidelberg, VIC, Australia.
  • Melbourne Medical School, Melbourne Brain Centre at Royal Melbourne Hospital, The University of Melbourne, Parkville, VIC, Australia.
  • Department of Surgery, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Fitzroy, VIC, 3065, Australia.

Förderung

  • Royal Australian and New Zealand College of Radiologists

Zitieren

APA

Wang, Q., Guo, X., Hornsey, E., McKenna, L., Churilov, L., Brooks, M., Matalanis, G., Chuen, J., Poon, E., Staeb, D., Jin, N., Ooi, A., & Lim, R. P. (2024). Performance of respiratory gated 4D flow MRI with adaptive k-space reordering in healthy controls and aortic dissection: reproducibility and agreement with 2D phase contrast MRI. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03298-2

Vancouver

Wang Q, Guo X, Hornsey E, McKenna L, Churilov L, Brooks M, et al. Performance of respiratory gated 4D flow MRI with adaptive k-space reordering in healthy controls and aortic dissection: reproducibility and agreement with 2D phase contrast MRI. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03298-2

BibTeX
@article{Wang2024,
  author = {Wang, Qingdi and Guo, Xiaojing and Hornsey, Emma and McKenna, Lucy and Churilov, Leonid and Brooks, Mark and Matalanis, George and Chuen, Jason and Poon, Eric and Staeb, Daniel and Jin, Ning and Ooi, Andrew and Lim, Ruth P},
  title = {Performance of respiratory gated 4D flow MRI with adaptive k-space reordering in healthy controls and aortic dissection: reproducibility and agreement with 2D phase contrast MRI},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2024},
  doi = {10.1007/s10554-024-03298-2}
}
Kostenlos starten →