ECHO-MPS, a dual modality strategy of cardiac imaging to identify myocardial ischemia
The International Journal of Cardiovascular Imaging · 2024
DOI: 10.1007/s10554-024-03257-x ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Cezary A Szmigielski und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, University of Oxford, Oxford, UK. cezary.szmigielski@wum.edu.pl. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Predictive Value of Tests. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Oxford NIHR Biomedical Research Centre.
Abstract (Originalsprache)
Purpose
We aimed to evaluate an approach with resting echocardiography (TTE) and stress myocardial perfusion scintigraphy (MPS) compared to standard MPS in patients with stable angina and normal left ventricle (LV). We hypothesized that normal LV on TTE may allow for the elimination of rest MPS without compromising accuracy and offering an efficient diagnostic pathway with reduced radiation exposure.
Methods
In a prospective, non-randomized study TTE was performed prior to MPS in patients (pts) referred for assessment of coronary artery disease (CAD). In pts with normal LV assessment was performed using the hybrid and the standard approach. TTE and MPS were interpreted by two TTE readers (ER1-2) and two MPS readers (NR1-2). ECHO-MPS was compared with standard MPS for diagnostic accuracy.
Results
103 patients, mean age 61 ± 12 year, (63 M, 40 W) were recruited. Standard MPS were normal in 75 patients and abnormal in 28 patients, with the hybrid approach 79 studies were reported as normal and 24 studies as abnormal. Kappa values were 0.580, ( p < 0.001) for large, 0.394, ( p < 0.001) for medium, and 0.298 ( p = 0.002) for small defects. With standard MPS as a reference, sensitivity for detection of perfusion defects by ECHO-MPS was 75% (95% CI 0.67–0.83) [NR2] and 78% (95% CI 0.70–0.86)[NR1]. Specificity was 95% (95% CI 0.90–0.99) [NR2] and 95% (CI 95%CI 0.90–0.99) [NR1].
Conclusions
ECHO-MPS protocol provides similar diagnostic accuracy as standard stress-rest MPS. In patients with normal systolic LV function in TTE, performing only stress MPS provides similar information as standard rest and stress MPS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, University of Oxford, Oxford, UK. cezary.szmigielski@wum.edu.pl.
- Department of Internal Medicine Hypertension and Vascular Diseases, Medical University of Warsaw, UCK CSK, 1A Banacha Street, Warsaw, 02-097, Poland. cezary.szmigielski@wum.edu.pl.
- Department of Cardiology, John Radcliffe Hospital, Oxford, OX3 9DU, UK.
- Department of Cardiovascular Medicine, University of Oxford, Oxford, UK.
- Division of Cardiology, Mazankowski Alberta Heart Institute, University of Alberta, Edmonton, Canada.
Förderung
- The Oxford NIHR Biomedical Research Centre
Zitieren
APA
Szmigielski, C. A., Sabharwal, N., Newton, J. D., & Becher, H. (2024). ECHO-MPS, a dual modality strategy of cardiac imaging to identify myocardial ischemia. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03257-x
Vancouver
Szmigielski CA, Sabharwal N, Newton JD, Becher H. ECHO-MPS, a dual modality strategy of cardiac imaging to identify myocardial ischemia. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03257-x
BibTeX
@article{Szmigielski2024,
author = {Szmigielski, Cezary A and Sabharwal, Nikant and Newton, James D and Becher, Harald},
title = {ECHO-MPS, a dual modality strategy of cardiac imaging to identify myocardial ischemia},
journal = {The International Journal of Cardiovascular Imaging},
year = {2024},
doi = {10.1007/s10554-024-03257-x}
}
EUVIMED