EUVIMEDEUVIMED entdecken
Vergleichsstudie

Predominant determinants for evaluation of right parasternal approach in transthoracic echocardiography in aortic stenosis: a study based on three-dimensional cardiac computed tomography analysis

Daisuke Yokokawa, Yui Kuroki, Yasuhide Mochizuki, Ayaka Oda, Sakiko Gohbara, Yumi Yamamoto, Saaya Ichikawa-Ogura, Rumi Hachiya, Eiji Toyosaki, Hiroto Fukuoka, Masataka Sunagawa, Toshiro Shinke

The International Journal of Cardiovascular Imaging · 2024

DOI: 10.1007/s10554-024-03160-5 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Daisuke Yokokawa und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-Ku, Tokyo, 142-8555, Japan. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Predictive Value of Tests, Multidetector Computed Tomography, Aortic Valve. Die Arbeit nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The maximum blood flow velocity through the aortic valve (AVmax) using Doppler transthoracic echocardiography (TTE) is important in assessing the severity of aortic stenosis (AS). The right parasternal (RP) approach has been reported to be more useful than the apical approach, but the anatomical rationale has not been studied. We aimed to clarify the influence of the angle formed by the ascending aorta and left ventricle on Doppler analysis by TTE (Sep-Ao angle) and three-dimensional multidetector computed tomography (3D-MDCT) in patients with AS. A total of 151 patients evaluated using the RP approach and 3D-MDCT were included in this study. The Sep-Ao angle determined using TTE was compared with that determined using 3D-MDCT analysis. In MDCT analysis, the left ventricular (LV) axis was measured in two ways and the calcification score was calculated simultaneously. The Sep-Ao angle on TTE was consistent with that measured using 3D-MDCT. In patients with an acute Sep-Ao angle, the Doppler angle in the apical approach was larger, potentially underestimating AVmax. Multivariate analysis revealed that an acute Sep-Ao angle, large Doppler angle in the apical approach, smaller Doppler angle in the RP approach, and low aortic valve calcification were independently associated with a higher AVmax in the RP approach than in the apical approach. The Sep-Ao angle measured using TTE reflected the 3D anatomical angle. In addition to measurements using the RP approach, technical adjustments to minimize the Doppler angle to avoid bulky calcification should always be noted for accurate assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisPredictive Value of TestsMultidetector Computed TomographyAortic ValveSeverity of Illness IndexHumansMaleFemaleAgedAged, 80 and overMiddle AgedBlood Flow VelocityReproducibility of ResultsEchocardiography, DopplerCalcinosisRetrospective StudiesImaging, Three-DimensionalMultivariate AnalysisAorta

Stichwörter der Autor:innen

Aortic stenosisDoppler angleRight parasternal approachThree-dimensional multidetector computed tomographyTransthoracic echocardiography

Autor:innen und Institutionen

  • Division of Cardiology, Department of Medicine, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-Ku, Tokyo, 142-8555, Japan.
  • Ultrasound Examination Center, Showa University, Tokyo, Japan.
  • Division of Cardiology, Department of Medicine, Showa University School of Medicine, 1-5-8 Hatanodai, Shinagawa-Ku, Tokyo, 142-8555, Japan. y_mochizuki@med.showa-u.ac.jp.
  • Department of Physiology, Showa University Graduate School of Medicine, Tokyo, Japan.

Zitieren

APA

Yokokawa, D., Kuroki, Y., Mochizuki, Y., Oda, A., Gohbara, S., Yamamoto, Y., Ichikawa-Ogura, S., Hachiya, R., Toyosaki, E., Fukuoka, H., Sunagawa, M., & Shinke, T. (2024). Predominant determinants for evaluation of right parasternal approach in transthoracic echocardiography in aortic stenosis: a study based on three-dimensional cardiac computed tomography analysis. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03160-5

Vancouver

Yokokawa D, Kuroki Y, Mochizuki Y, Oda A, Gohbara S, Yamamoto Y, et al. Predominant determinants for evaluation of right parasternal approach in transthoracic echocardiography in aortic stenosis: a study based on three-dimensional cardiac computed tomography analysis. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03160-5

BibTeX
@article{Yokokawa2024,
  author = {Yokokawa, Daisuke and Kuroki, Yui and Mochizuki, Yasuhide and Oda, Ayaka and Gohbara, Sakiko and Yamamoto, Yumi and Ichikawa-Ogura, Saaya and Hachiya, Rumi and Toyosaki, Eiji and Fukuoka, Hiroto and Sunagawa, Masataka and Shinke, Toshiro},
  title = {Predominant determinants for evaluation of right parasternal approach in transthoracic echocardiography in aortic stenosis: a study based on three-dimensional cardiac computed tomography analysis},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2024},
  doi = {10.1007/s10554-024-03160-5}
}
Kostenlos starten →