Discordance interpretation of left ventricular size between echocardiography and cardiac magnetic resonance in pediatric patients with aortic/mitral regurgitation
The International Journal of Cardiovascular Imaging · 2024
DOI: 10.1007/s10554-024-03073-3 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The International Journal of Cardiovascular Imaging, 2024. Verfasst von Anastasia Barros und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nemours Children's Health, Wilmington, DE, USA. anastasia.barros23@gmail.com. Hauptthemen laut MEDLINE: Predictive Value of Tests, Ventricular Function, Left, Mitral Valve Insufficiency, Stroke Volume. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
This study investigated discordance between echocardiography (echo) and cardiac magnetic resonance (CMR) measurements of the left ventricle (LV) in pediatric patients with aortic and/or mitral regurgitation (AR/MR).
Methods
Retrospective cohort study of pediatric patients. The cohorts were comprised of patients with AR/MR vs. non-AR/MR. Left ventricular end diastolic volume (LVEDV) by CMR and left ventricular internal diameter diastolic (LVIDd) by echo were obtained from clinical reports then echo images were reviewed to remeasure LVEDV by bullet method. Left ventricular internal diameter systolic (LVIDs) and left ventricular ejection fraction (LVEF) measurements by echo and LVEF by CMR were obtained from clinical reports. Fractional shortening (FS%) was recalculated. Z-scores were calculated using normative data. Correlation between echo and CMR LV measurements was assessed using correlation coefficients. Bland-Altman plots assessed bias between imaging modalities. Receiver operator characteristic (ROC) analysis was performed for detection of LV enlargement and LV dysfunction.
Results
AR/MR patients had greater discrepancy in LV size interpretation by Z-score compared to non-AR/MR patients. This discrepancy persisted when the bullet method short axis measurements were incorporated. There was negative bias in echo-based measurements compared to CMR. The diagnostic performance of echo in identifying moderate LV enlargement was worse for AR/MR pediatrics patients.
Conclusion
The discordant interpretation of LV size by echo compared to CMR is worse in pediatric patients with AR/MR when compared to patients without AR/MR even when short axis measurements are incorporated. This finding suggests non-uniform geometrical changes in the LV as it enlarges due to AR/MR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Nemours Children's Health, Wilmington, DE, USA. anastasia.barros23@gmail.com.
- Children's National Hospital, Washington, DC, USA.
- Children's Hospital of Pittsburgh of UPMC, Pittsburgh, PA, USA.
Zitieren
APA
Barros, A., Udine, M., Spurney, C., Olivieri, L., & Loke, Y. H. (2024). Discordance interpretation of left ventricular size between echocardiography and cardiac magnetic resonance in pediatric patients with aortic/mitral regurgitation. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-024-03073-3
Vancouver
Barros A, Udine M, Spurney C, Olivieri L, Loke YH. Discordance interpretation of left ventricular size between echocardiography and cardiac magnetic resonance in pediatric patients with aortic/mitral regurgitation. The International Journal of Cardiovascular Imaging. 2024. doi:10.1007/s10554-024-03073-3
BibTeX
@article{Barros2024,
author = {Barros, Anastasia and Udine, Michelle and Spurney, Chris and Olivieri, Laura and Loke, Yue-Hin},
title = {Discordance interpretation of left ventricular size between echocardiography and cardiac magnetic resonance in pediatric patients with aortic/mitral regurgitation},
journal = {The International Journal of Cardiovascular Imaging},
year = {2024},
doi = {10.1007/s10554-024-03073-3}
}
EUVIMED