EUVIMEDEUVIMED entdecken
Crossref

Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population

Makoto Orii, Misato Sone, Takeshi Osaki, Kei Kikuchi, Tsuyoshi Sugawara, Xucheng Zhu, Martin A Janich, Atsushi Nozaki, Kunihiro Yoshioka

The International Journal of Cardiovascular Imaging · 2023

DOI: 10.1007/s10554-023-02793-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The International Journal of Cardiovascular Imaging, 2023. Verfasst von Makoto Orii und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan. kori931@gmail.com. Hauptthemen laut MEDLINE: Deep Learning. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to assess the image quality and accuracy of respiratory-gated real-time two-dimensional (2D) cine incorporating deep learning reconstruction (DLR) for the quantification of biventricular volumes and function compared with those of the standard reference, that is, breath-hold 2D balanced steady-state free precession (bSSFP) cine, in an adult population. Twenty-four patients (15 men, mean age 50.7 ± 16.5 years) underwent cardiac magnetic resonance for clinical indications, and 2D DLR and bSSFP cine were acquired on the short-axis view. The image quality scores were based on three main criteria: blood-to-myocardial contrast, endocardial edge delineation, and presence of motion artifacts throughout the cardiac cycle. Biventricular end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), and left ventricular mass (LVM) were analyzed. The 2D DLR cine had significantly shorter scan time than bSSFP (41.0 ± 11.3 s vs. 327.6 ± 65.8 s; p 0.05). Moreover, the linear regression yielded good agreement between the two techniques (r ≥ 0.76). However, the LVM was underestimated for DLR cine (109.8 ± 34.6 g) compared with that for bSSFP (116.2 ± 40.2 g; p = 0.0291). Respiratory-gated 2D DLR cine is a reliable technique that could be used in the evaluation of biventricular volumes and function in an adult population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningMaleAdultHumansMiddle AgedAgedReproducibility of ResultsPredictive Value of TestsMagnetic Resonance Imaging, CineStroke VolumeVentricular Function

Stichwörter der Autor:innen

Balanced steady-state free precessionCardiac magnetic resonance imagingRespiratory-gated real-time two-dimensional cine incorporating deep learning re…Ventricular function

Autor:innen und Institutionen

  • Department of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan. kori931@gmail.com.
  • Department of Radiology, Iwate Medical University, 2-1-1, Idaidori, Yahaba, 028-3695, Iwate, Japan.
  • Department of Radiology Service, Iwate Medical University, Iwate, Japan.
  • GE Healthcare, Menlo Park, CA, USA.
  • GE Healthcare, Munich, Germany.
  • GE Healthcare, Tokyo, Japan.

Zitieren

APA

Orii, M., Sone, M., Osaki, T., Kikuchi, K., Sugawara, T., Zhu, X., Janich, M. A., Nozaki, A., & Yoshioka, K. (2023). Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-023-02793-2

Vancouver

Orii M, Sone M, Osaki T, Kikuchi K, Sugawara T, Zhu X, et al. Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population. The International Journal of Cardiovascular Imaging. 2023. doi:10.1007/s10554-023-02793-2

BibTeX
@article{Orii2023,
  author = {Orii, Makoto and Sone, Misato and Osaki, Takeshi and Kikuchi, Kei and Sugawara, Tsuyoshi and Zhu, Xucheng and Janich, Martin A and Nozaki, Atsushi and Yoshioka, Kunihiro},
  title = {Reliability of respiratory-gated real-time two-dimensional cine incorporating deep learning reconstruction for the assessment of ventricular function in an adult population},
  journal = {The International Journal of Cardiovascular Imaging},
  year = {2023},
  doi = {10.1007/s10554-023-02793-2}
}
Kostenlos starten →