An inexpensive, portable, refrigeration-free, ready-to-use microfluidic device for real-time multiplexed molecular detection of HIV, HBV, and HCV
Biomedical Microdevices · 2026-06 · 28 (2)
DOI: 10.1007/s10544-026-00830-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Microdevices, online erschienen am 29.05.2026. Verfasst von Huiwen Bai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 233 Towne Building…. Hauptthemen laut MEDLINE: Hepatitis B virus, Hepacivirus, HIV, Lab-On-A-Chip Devices. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
Human immunodeficiency virus (HIV), Hepatitis B virus (HBV), and Hepatitis C virus (HCV) have infected or co-infected more than 400 million people worldwide and are becoming one of the most significant challenges for global healthcare. A simple, rapid, point-of-care diagnosis is playing a key role in controlling the spreading of these diseases and providing proper care for each patient. In this study, we have developed an inexpensive, portable, refrigeration-free, ready-to-use microfluidic device for multiplexed detection of HIV, HBV, and HCV, which is amenable to point-of-care application when combined with a simple upstream sample-preparation step. All reagents and essential components for nucleic acid amplification are fully dried on chip and can last for at least 10 weeks being exposed to the atmosphere at room temperature. The device operation only involves the manipulation of target-containing sample solutions without any need for chemical handling operated by skilled personnel. Built-in capillary circuits provide auto-distribution of sample solution and perform auto-sealing with a phase-change material. The chip consists of four reaction chambers for HIV, HBV, HCV, and one negative control, respectively. Each reaction chamber can release both colorimetric and fluorometric signals during amplification with the presence of target nucleic acids. The amplifications on chip were monitored in real time, and the device detected down to 24 copies of HBV DNA and 76 copies of HCV RNA during the 60-min on-chip amplification. All procedures were conducted using a portable custom processor comprising an electric resistance heater and a USB camera, which can be readily reproduced in resource-limited settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 233 Towne Building, 220 S. 33rd Street, Philadelphia, PA, 19104, USA.
- Department of Biotechnology and Bioengineering, Chonnam National University, Gwangju, 61186, Republic of Korea.
- Department of Biomaterial Convergence, Chonnam National University, Gwangju, 61186, Republic of Korea.
- Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 29 Zhongguancun East Road, Haidian District, Beijing, 100190, China.
- Department of Mechanical and Aerospace Engineering, NYU Tandon School of Engineering, 6 MetroTech Center, Brooklyn, NY, 11201, USA.
- Department of Mechanical Engineering and Applied Mechanics, School of Engineering and Applied Science, University of Pennsylvania, 233 Towne Building, 220 S. 33rd Street, Philadelphia, PA, 19104, USA. bau@seas.upenn.edu.
Zitieren
APA
Bai, H., Lee, S., Li, R., Yin, Q., Bau, H. H., & Seok, Y. (2026). An inexpensive, portable, refrigeration-free, ready-to-use microfluidic device for real-time multiplexed molecular detection of HIV, HBV, and HCV. Biomedical Microdevices, 28(2). https://doi.org/10.1007/s10544-026-00830-0
Vancouver
Bai H, Lee S, Li R, Yin Q, Bau HH, Seok Y. An inexpensive, portable, refrigeration-free, ready-to-use microfluidic device for real-time multiplexed molecular detection of HIV, HBV, and HCV. Biomedical Microdevices. 2026;28(2). doi:10.1007/s10544-026-00830-0
BibTeX
@article{Bai2026,
author = {Bai, Huiwen and Lee, Sangmin and Li, Ruijie and Yin, Qingtian and Bau, Haim H and Seok, Youngung},
title = {An inexpensive, portable, refrigeration-free, ready-to-use microfluidic device for real-time multiplexed molecular detection of HIV, HBV, and HCV},
journal = {Biomedical Microdevices},
year = {2026},
volume = {28},
number = {2},
doi = {10.1007/s10544-026-00830-0}
}
EUVIMED