Construction of a pumpless gravity-driven vascularized Skin-on-a-Chip for the study of hepatocytotoxicity in percutaneous exposure to exogenous chemicals

Su Zhou, Rui Li, Jie Sun, Minyang Gu, Dan Gao, Liming Tang, Jiangbo Zhu

Biomedical Microdevices · 2024

DOI: 10.1007/s10544-024-00723-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Microdevices, 2024. Verfasst von Su Zhou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Toxicology, College of Naval Medicine, Naval Medical University, Shanghai, 200433, China. Hauptthemen laut MEDLINE: Human Umbilical Vein Endothelial Cells, Skin, Lab-On-A-Chip Devices, Hepatocytes. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Major Project on Military Logistics Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The utilization of existing Skin-on-a-Chip (SoC) is constrained by the complex structures, the multiplicity of auxiliary devices, and the inability to evaluate exogenous chemicals that are hepatotoxic after percutaneous metabolism. In this study, a gravity-driven SoC without any auxiliary devices was constructed for the hepatocytotoxicity study of exogenous chemicals. The SoC possesses 3 layers of culture chambers, from top to bottom, for human skin equivalent (HSE), Human Umbilical Vein Endothelial Cells (HUVEC) and hepatocytes (HepG2), and the maintenance and expression capacity of the corresponding cells on the SoC were verified by specificity parameters. The reactivity of the SoC to exogenous chemicals was verified by 2-aminofluorene (2-AF). The SoC can realistically simulate the in vivo exposure process of exogenous chemicals that are percutaneously exposed and metabolized into the bloodstream and then to the liver to produce toxicity, and it can achieve the same effects on transcriptome as those of animal tests at lower exposure levels while examining multiple toxicological targets of the skin, vascular endothelial cells, and hepatocytes. Both in terms of species similarity, the principles of reduction, replacement and refinement (3R), or the level of exposure suggest that the present SoC has a degree of replacement for animal models in assessing exogenous chemicals, especially those that are hepatotoxic after percutaneous metabolism.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Human Umbilical Vein Endothelial CellsSkinLab-On-A-Chip DevicesHepatocytesHumansHep G2 CellsGravitationLiverToxicity Tests

Stichwörter der Autor:innen

2-aminofluoreneHepatocyte metabolismMicrofluidicN-acetylationSkin-on-a-Chip

Autor:innen und Institutionen

  • Department of Health Toxicology, College of Naval Medicine, Naval Medical University, Shanghai, 200433, China.
  • Pharmacology and Toxicology Department, Shanghai Institute for Food and Drug Control, Shanghai, 201203, China.
  • Department of Health Toxicology, College of Naval Medicine, Naval Medical University, Shanghai, 200433, China. jiangbozhu1@163.com.

Förderung

  • National Natural Science Foundation of China
  • Major Project on Military Logistics Research

Zitieren

APA

Zhou, S., Li, R., Sun, J., Gu, M., Gao, D., Tang, L., & Zhu, J. (2024). Construction of a pumpless gravity-driven vascularized Skin-on-a-Chip for the study of hepatocytotoxicity in percutaneous exposure to exogenous chemicals. Biomedical Microdevices. https://doi.org/10.1007/s10544-024-00723-0

Vancouver

Zhou S, Li R, Sun J, Gu M, Gao D, Tang L, et al. Construction of a pumpless gravity-driven vascularized Skin-on-a-Chip for the study of hepatocytotoxicity in percutaneous exposure to exogenous chemicals. Biomedical Microdevices. 2024. doi:10.1007/s10544-024-00723-0

BibTeX
@article{Zhou2024,
  author = {Zhou, Su and Li, Rui and Sun, Jie and Gu, Minyang and Gao, Dan and Tang, Liming and Zhu, Jiangbo},
  title = {Construction of a pumpless gravity-driven vascularized Skin-on-a-Chip for the study of hepatocytotoxicity in percutaneous exposure to exogenous chemicals},
  journal = {Biomedical Microdevices},
  year = {2024},
  doi = {10.1007/s10544-024-00723-0}
}
Kostenlos starten →