EUVIMEDEUVIMED entdecken
Crossref

Fluid–Structure Interaction Analysis of Human Eye with Descemet Membrane Detachment

Ammar I Alsabery, Muneer A Ismael, Zehba Raizah, Mohammad Ghalambaz, Ishak Hashim

Annals of Biomedical Engineering · 06.08.2026

DOI: 10.1007/s10439-026-04317-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Biomedical Engineering, online erschienen am 06.08.2026. Verfasst von Ammar I Alsabery und 4 weiteren Autor:innen. Beteiligte Einrichtung: Refrigeration & Air-Conditioning Technical Engineering Department, College of Technical Engineering, The Islamic University, Najaf, Iraq. ammar_e_201…. Die Arbeit nennt 53 Literaturangaben. Gefördert von: Universiti Kebangsaan Malaysia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detachment of Descemet membrane (DM) is a defect that occurs in the cornea of the human eye. Most previous examinations have focused on relatively simple benchmarks, excluding the complex interaction between intraocular fluid flow and delicate ocular structures such as the Descemet membrane, particularly in detachment issues. This paper simulates the detached DM as a flexible membrane to explore the convection inside the anterior chamber (AC) of human eye and to evaluate the cornea transplantation processes. The analysis is conducted numerically by considering the mixed heat transmission and the fluid–structure interaction (FSI) within a geometry representing the AC. The study of FSI facilitates the simulation of different elasticity modulus E of the detached DM ( $$E = 10^{8}$$ E = 10 8 to $$10^{11}$$ 10 11 ), which enables the study of various corneas implemented in transplantation processes. Rayleigh number is varied from $$10^{3}$$ 10 3 to $$10^{6}$$ 10 6 to simulate thermal therapy of temperature difference from 0.25 to 250 K. The length of the iris accounts the length of the contacting part of the lens S having the isothermal hot temperature is also explored. Results reveal that the cornea type affects the stress imparted on the DDM and does not affect the thermal characteristics or the displacement within the anterior chamber. The shrinkage of the iris elevates the convective thermal characteristic by about 78%. Elevating the thermal therapy $$\Delta T$$ Δ T from 2.5 to 25 K promotes the heat transfer by 47.6%.

Schlagwörter

Stichwörter der Autor:innen

Anterior chamber flowCorneaDescemet membrane detachmentFSIHuman eye

Autor:innen und Institutionen

  • Refrigeration & Air-Conditioning Technical Engineering Department, College of Technical Engineering, The Islamic University, Najaf, Iraq. ammar_e_2011@yahoo.com.
  • Mechanical Engineering Department, Engineering College, University of Basrah, Basra, 61004, Iraq.
  • College of Engineering, University of Warith Al-Anbiyaa, Karbalā', Iraq.
  • Department of Mathematics, College of Science, King Khalid University, Abha, Saudi Arabia.
  • Department of Mathematical Sciences, Saveetha School of Engineering, SIMATS, Chennai, India.
  • Department Mathematical Sciences, Faculty of Science & Technology, Universiti Kebangsaan Malaysia, UKM, 43600, Bangi, Selangor, Malaysia.

Förderung

  • Universiti Kebangsaan Malaysia

Zitieren

APA

Alsabery, A. I., Ismael, M. A., Raizah, Z., Ghalambaz, M., & Hashim, I. (2026). Fluid–Structure Interaction Analysis of Human Eye with Descemet Membrane Detachment. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-026-04317-0

Vancouver

Alsabery AI, Ismael MA, Raizah Z, Ghalambaz M, Hashim I. Fluid–Structure Interaction Analysis of Human Eye with Descemet Membrane Detachment. Annals of Biomedical Engineering. 2026. doi:10.1007/s10439-026-04317-0

BibTeX
@article{Alsabery2026,
  author = {Alsabery, Ammar I and Ismael, Muneer A and Raizah, Zehba and Ghalambaz, Mohammad and Hashim, Ishak},
  title = {Fluid–Structure Interaction Analysis of Human Eye with Descemet Membrane Detachment},
  journal = {Annals of Biomedical Engineering},
  year = {2026},
  doi = {10.1007/s10439-026-04317-0}
}
Kostenlos starten →