Fachartikel in der Zeitschrift Annals of Biomedical Engineering, online erschienen am 20.07.2026. Verfasst von Samuel Hopkins und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Northern Arizona University, Sanghi College of Engineering, Flagstaff, AZ, USA. ssh252@nau.edu. Die Arbeit nennt 38 Literaturangaben. Gefördert von: Flinn Foundation.
Abstract (Originalsprache)
Purpose
Individuals who wear Ankle Foot Orthoses (AFOs) express a desire for adaptability and improved stair ambulation. This exploratory study examined how the stiffness and neutral angle of a robotic AFO influence stair ambulation and preference in spastic cerebral palsy (CP) and compared robotic AFOs, solid AFOs, and shoes alone.
Methods
Seven individuals with spastic CP completed modified Timed-Up-and-Down-Stairs (TUDS) tests under nine robotic AFO stiffness-neutral angle configurations, solid AFOs, and shoes alone. Outcomes included TUDS time, ankle kinematics, soleus and vastus lateralis activity, exertion, balance confidence, trunk instability, stiffness preference, and device power and torque. Mixed effects modeling assessed the effects of stiffness and neutral angle. Stiffness preference was evaluated during level walking, stair ascent, and descent. Repeated measures ANOVA compared robotic AFOs, solid AFOs, and shoes alone.
Results
Increased stiffness and more plantarflexed neutral angles decreased peak dorsiflexion (p < 0.05) and increased peak torque (p < 0.05). Few other outcomes were affected. Four of seven participants preferred low stiffness across all tasks. Robotic AFOs performed better than solid AFOs, by decreasing TUDs time (− 27%, d = − 0.66, p < 0.05) and increasing confidence (49%, d = 0.92, p < 0.05) in descent, but not better than shoes alone. During stair ascent, the only difference between the AFOs and shoes was a reduction in soleus activity between solid AFOs and shoes alone.
Conclusion
Robotic AFO configuration influences stair descent and may improve descent speed and confidence over solid AFOs in a limited sample of spastic CP.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Northern Arizona University, Sanghi College of Engineering, Flagstaff, AZ, USA. ssh252@nau.edu.
- Department of Mechanical Engineering, Northern Arizona University, Sanghi College of Engineering, Flagstaff, AZ, USA.
- College of Medicine-Phoenix, University of Arizona, Phoenix, AZ, USA.
Förderung
- Flinn Foundation
Zitieren
APA
Hopkins, S., Gaudette, C., Silvetti, M. J., & Lerner, Z. F. (2026). Exploratory Assessment of Robotic Ankle Foot Orthosis Stiffness and Neutral Angle on Stair Ambulation in Individuals with Cerebral Palsy. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-026-04305-4
Vancouver
Hopkins S, Gaudette C, Silvetti MJ, Lerner ZF. Exploratory Assessment of Robotic Ankle Foot Orthosis Stiffness and Neutral Angle on Stair Ambulation in Individuals with Cerebral Palsy. Annals of Biomedical Engineering. 2026. doi:10.1007/s10439-026-04305-4
BibTeX
@article{Hopkins2026,
author = {Hopkins, Samuel and Gaudette, Connor and Silvetti, Maria Jose and Lerner, Zachary F},
title = {Exploratory Assessment of Robotic Ankle Foot Orthosis Stiffness and Neutral Angle on Stair Ambulation in Individuals with Cerebral Palsy},
journal = {Annals of Biomedical Engineering},
year = {2026},
doi = {10.1007/s10439-026-04305-4}
}
EUVIMED