The CathPilot: Usability and Feasibility Evaluation in Simulated-Use Endovascular Interventions
Annals of Biomedical Engineering · 09.07.2026
DOI: 10.1007/s10439-026-04255-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, online erschienen am 09.07.2026. Verfasst von Sina Mohammadmahdi Keshavarz und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada. mkeshavarz@torontomu.ca. Die Arbeit nennt 37 Literaturangaben. Gefördert von: Canada Research Chairs, Natural Sciences and Engineering Research Council of Canada, Ministère de l'Éducation, Gouvernement de l'Ontario.
Abstract (Originalsprache)
Endovascular treatment of complex peripheral artery disease and chronic total occlusions remains a significant challenge. This is largely due to limited distal control of devices used and reliance on proximal manipulation with conventional catheters. To bridge this gap, we previously developed the CathPilot, a modular steerable catheter that integrates a self-expanding nitinol frame for local anchoring with a real-time graphical user interface that provides cross-sectional tip position feedback alongside fluoroscopy. This study compares the CathPilot with conventional non-steerable catheters in a simulated-use, within-subjects design. Eight interventional clinicians each performed three lesion-crossing attempts per device in a silicone phantom model of human vasculature. Silicone lesions were positioned in the left superficial femoral artery. Objective endpoints included lesion-crossing success, procedure time, fluoroscopy time, and radiation dose. Subjective assessments included the System Usability Scale (SUS) for perceived usability and NASA Task Load Index (NASA-TLX) for operator workload. Combining objective performance with human-factors instruments enabled a comprehensive assessment of the CathPilot's procedural usability against conventional catheters. CathPilot achieved a 92% lesion-crossing success rate with approximately 3 × improvement compared to conventional catheters. Clinician-level and lesion-level procedure times, and fluoroscopy times were significantly lower when using the CathPilot. Similarly, the NASA-TLX workload rating was significantly lower for CathPilot. Under simulated-use conditions, these findings indicate the potential of the CathPilot system to address endovascular revascularization challenges and demonstrate the added value of precise distal tip control, tracking, and support.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada. mkeshavarz@torontomu.ca.
- Magellan Biomedical Inc., Toronto, Canada. mkeshavarz@torontomu.ca.
- Sunnybrook Research Institute, Toronto, Canada. mkeshavarz@torontomu.ca.
- Department of Biomedical Engineering, Toronto Metropolitan University, Toronto, Canada.
- Magellan Biomedical Inc., Toronto, Canada.
- Sunnybrook Research Institute, Toronto, Canada.
Förderung
- Canada Research Chairs
- Natural Sciences and Engineering Research Council of Canada
- Ministère de l'Éducation, Gouvernement de l'Ontario
- Canada Foundation for Innovation
- Ministère de l’Éducation, Gouvernement de l’Ontario
Zitieren
APA
Keshavarz, S. M., Zhou, J., Sewani, A., Cai, S., Wright, G., Dueck, A., & Tavallaei, M. A. (2026). The CathPilot: Usability and Feasibility Evaluation in Simulated-Use Endovascular Interventions. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-026-04255-x
Vancouver
Keshavarz SM, Zhou J, Sewani A, Cai S, Wright G, Dueck A, et al. The CathPilot: Usability and Feasibility Evaluation in Simulated-Use Endovascular Interventions. Annals of Biomedical Engineering. 2026. doi:10.1007/s10439-026-04255-x
BibTeX
@article{Keshavarz2026,
author = {Keshavarz, Sina Mohammadmahdi and Zhou, James and Sewani, Alykhan and Cai, Sharon and Wright, Graham and Dueck, Andrew and Tavallaei, M Ali},
title = {The CathPilot: Usability and Feasibility Evaluation in Simulated-Use Endovascular Interventions},
journal = {Annals of Biomedical Engineering},
year = {2026},
doi = {10.1007/s10439-026-04255-x}
}
EUVIMED