Airborne Ultrasound Surface Motion Camera: Application to Transfer Admittance Chest Imaging
Annals of Biomedical Engineering · 08.07.2026
DOI: 10.1007/s10439-026-04252-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, online erschienen am 08.07.2026. Verfasst von Frédéric Wintzenrieth und 6 weiteren Autor:innen. Beteiligte Einrichtung: AUSTRAL Diagnostics, 24 rue du Faubourg St-Jacques, Paris, 75014, France. fwintz@australdx.fr. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
Lung mechanics are heterogeneous in virtually all respiratory diseases. Spatially mapping this heterogeneity without ionizing radiation and at bedside is not feasible with current techniques. Here, we use an Airborne Ultrasound Surface Motion Camera (AUSMC) to map the local transfer admittance of the respiratory system, in response to an oscillatory pressure source at the mouth. As a proof of concept, the local admittance maps are shown for two individuals: a COPD patient and an age-matched healthy subject. The system measures a far lower transfer admittance in the subject with COPD compared to the normal control. The consistency of this result is tested comparing interquartile ranges of the regional transfer admittance and impedance of 6 COPD patients vs 6 healthy subjects. Trial Registration Number: ClinicalTrials.gov NCT06661200. Registered on October 17th 2024.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- AUSTRAL Diagnostics, 24 rue du Faubourg St-Jacques, Paris, 75014, France. fwintz@australdx.fr.
- AUSTRAL Diagnostics, 24 rue du Faubourg St-Jacques, Paris, 75014, France.
- Department of Cardiac & Pulmonary Function Testing, University Hospital of Caen, avenue de la Côte de Nacre CS 30001, Caen, 14000, Normandy, France.
- UR 4650 PSIR, GIP CYCERON, Campus Jules Horowitz, Bd Henri Becquerel, 14074, Caen, France.
- Institut Langevin, CNRS, ESPCI Paris, PSL Research University, 1 rue Jussieu, Paris Cedex 05, 75238, France.
- Department of Pulmonology & Physiology, University Grenoble Alpes, STROBE Inserm UA7, Grenoble, 38000, France.
Zitieren
APA
Wintzenrieth, F., Couade, M., Mouadil, A., Saloux, É., Fink, M., Ing, R. K., & Bayat, S. (2026). Airborne Ultrasound Surface Motion Camera: Application to Transfer Admittance Chest Imaging. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-026-04252-0
Vancouver
Wintzenrieth F, Couade M, Mouadil A, Saloux É, Fink M, Ing RK, et al. Airborne Ultrasound Surface Motion Camera: Application to Transfer Admittance Chest Imaging. Annals of Biomedical Engineering. 2026. doi:10.1007/s10439-026-04252-0
BibTeX
@article{Wintzenrieth2026,
author = {Wintzenrieth, Frédéric and Couade, Mathieu and Mouadil, Amèle and Saloux, Éric and Fink, Mathias and Ing, Ros Kiri and Bayat, Sam},
title = {Airborne Ultrasound Surface Motion Camera: Application to Transfer Admittance Chest Imaging},
journal = {Annals of Biomedical Engineering},
year = {2026},
doi = {10.1007/s10439-026-04252-0}
}
EUVIMED