Generation of Fibrin-Based Aortic Vessels with Layer-Specific Cell Architecture Under Pulsatile Perfusion in a Clinical Organ Care System
Annals of Biomedical Engineering · 2026
DOI: 10.1007/s10439-026-04087-9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2026. Verfasst von Celina Delia Käding und 9 weiteren Autor:innen. Beteiligte Einrichtung: Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), Hannover Medical School, Hannover, Germany. Hauptthemen laut MEDLINE: Fibrin, Blood Vessel Prosthesis, Tissue Engineering, Aorta. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Else-Kröner-Fresenius-Foundation, Medizinische Hochschule Hannover (MHH).
Abstract (Originalsprache)
Purpose
Overcoming the limitations of synthetic vascular grafts in the development of biocompatible and regenerative vessels remains a long-term objective in tissue engineering. In this study, we engineered large-diameter fibrin-based vascular grafts with a target inner diameter of 21 mm replicating all three layers of the native human vessel wall in vitro.
Methods
The Tunica media was reconstructed using a compressed high-density (25 mg/mL) fibrin matrix seeded with smooth muscle cells expressing α-SMA and calponin, differentiated from adipose-derived mesenchymal stem cells (ASCs). The Adventitia -equivalent was formed in a 5 mg/mL fibrin gel containing ASCs, human umbilical vein endothelial cells (HUVECs), and normal human dermal fibroblasts (NHDFs) to enable the formation of a capillary-like network resembling the native adventitial Vasa vasorum . The luminal surface was endothelialized with HUVECs to replicate the Tunica intima . While controls were cultured statically for 7 days, other grafts were evaluated under pulsatile perfusion at physiological pressures using the TransMedics ® “Organ Care System Heart ™ ”.
Results
The stepwise fabrication technique resulted in three-layered bioartificial vessel equivalents with a mean inner diameter of 21 mm. All constructed vessels ( n = 3) maintained sufficient biomechanical stability to withstand physiological pressure (120.9 ± 1.2 to 61.4 ± 12.5 mmHg) at 60 bpm throughout the perfusion period. The aortic grafts exhibited a cyclic stretch (8.95 ± 2.03%) within the physiological range of native vessels. Mechanical stimulation induced a layer-specific physiological cell morphology and alignment across all three layers of the vascular wall. Endothelial coverage was high on static grafts (81.39 ± 2.37%) and on one of three dynamic grafts. Shear stress during perfusion (0.38 ± 0.03 dyn cm −2 ) remained below physiological levels, and further evaluation under prolonged perfusion (> 21 days) is required to assess long-term biomechanical stability and vascular functionality.
Conclusion
This approach may be considered a proof of concept and constitutes a first step toward the development of biometric and functional large-diameter vessel replacements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), Hannover Medical School, Hannover, Germany.
- Division for Cardiothoracic-, Transplantation-, and Vascular Surgery, Hannover Medical School, Hannover, Germany.
- Department of Vascular- and Endovascular Surgery, St. Bernward Hospital, Hildesheim, Germany.
- Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), Hannover Medical School, Hannover, Germany. Helms.florian@mh-hannover.de.
- Division for Cardiothoracic-, Transplantation-, and Vascular Surgery, Hannover Medical School, Hannover, Germany. Helms.florian@mh-hannover.de.
Förderung
- Else-Kröner-Fresenius-Foundation
- Medizinische Hochschule Hannover (MHH)
Zitieren
APA
Käding, C. D., Glomb, C. S., Stadler, P., Becker, I., Klingenberg, M., Höffler, H. K., Pflaum, M., Ruhparwar, A., Wilhelmi, M., & Helms, F. (2026). Generation of Fibrin-Based Aortic Vessels with Layer-Specific Cell Architecture Under Pulsatile Perfusion in a Clinical Organ Care System. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-026-04087-9
Vancouver
Käding CD, Glomb CS, Stadler P, Becker I, Klingenberg M, Höffler HK, et al. Generation of Fibrin-Based Aortic Vessels with Layer-Specific Cell Architecture Under Pulsatile Perfusion in a Clinical Organ Care System. Annals of Biomedical Engineering. 2026. doi:10.1007/s10439-026-04087-9
BibTeX
@article{Kding2026,
author = {Käding, Celina Delia and Glomb, Clara-Sophie and Stadler, Patrick and Becker, Imke and Klingenberg, Melanie and Höffler, Hans-Klaus and Pflaum, Michael and Ruhparwar, Arjang and Wilhelmi, Mathias and Helms, Florian},
title = {Generation of Fibrin-Based Aortic Vessels with Layer-Specific Cell Architecture Under Pulsatile Perfusion in a Clinical Organ Care System},
journal = {Annals of Biomedical Engineering},
year = {2026},
doi = {10.1007/s10439-026-04087-9}
}
EUVIMED