Field Evaluation of a Wearable Instrumented Headband Designed for Measuring Head Kinematics
Annals of Biomedical Engineering · 2026
DOI: 10.1007/s10439-026-04051-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2026. Verfasst von Anu Tripathi und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering, Robert Morris University, Moon Township, PA, USA. Hauptthemen laut MEDLINE: Head, Soccer, Wearable Electronic Devices. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Office of the Vice Chancellor for Research and Graduate Education, University of Wisconsin-Madison, Office of Naval Research.
Abstract (Originalsprache)
Purpose
To study the relationship between soccer heading and the risk of mild traumatic brain injury (mTBI), we previously developed an instrumented headband and data-processing scheme to measure the angular head kinematics of soccer headers. Laboratory evaluation of the headband on an anthropomorphic test device showed good agreement with a reference sensor for soccer ball impacts to the front of the head. In this study, we evaluate the headband in measuring the full head kinematics of soccer headers in the field.
Methods
The headband was evaluated under typical soccer heading scenarios (throw-ins, goal-kicks, and corner-kicks) on a human subject. The measured time history and peak kinematics from the headband were compared with those from an instrumented mouthpiece, which is a widely accepted method for measuring head kinematics in the field.
Results
The time-history agreement (CORA scores) between the headband and the mouthpiece ranged from ‘fair’ to ‘excellent’, with the highest agreement for angular velocities (0.79 ± 0.08) and translational accelerations (0.73 ± 0.05) and lowest for angular accelerations (0.67 ± 0.06). A Bland–Altman analysis of the peak kinematics from the headband and mouthpiece found the mean bias to be 40.9 $$\%$$ % (of the maximum mouthpiece reading) for the angular velocity, 16.6 $$\%$$ % for the translational acceleration, and −14.1 $$\%$$ % for the angular acceleration.
Conclusions
The field evaluation of the instrumented headband showed reasonable agreement with the mouthpiece for some kinematic measures and impact conditions. Future work should focus on improving the headband performance across all kinematic measures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering, Robert Morris University, Moon Township, PA, USA.
- School of Engineering, Brown University, Providence, RI, USA.
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA.
- Waisman Center, University of Wisconsin-Madison, Madison, WI, USA.
- Department of Electrical and Computer Engineering , University of Wisconsin Madison, Madison, USA.
- Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, WI, USA.
Förderung
- Office of the Vice Chancellor for Research and Graduate Education, University of Wisconsin-Madison
- Office of Naval Research
Zitieren
APA
Tripathi, A., Wan, Y., Zhu, Z., Camci, F., Turcsanyi, S., Kachhadiya, J. P., Araiza Canizales, M., Brooks, A., Kesari, H., Andrews, J., Snedden, T., Ferrazzano, P., Franck, C., & Carlsen, R. W. (2026). Field Evaluation of a Wearable Instrumented Headband Designed for Measuring Head Kinematics. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-026-04051-7
Vancouver
Tripathi A, Wan Y, Zhu Z, Camci F, Turcsanyi S, Kachhadiya JP, et al. Field Evaluation of a Wearable Instrumented Headband Designed for Measuring Head Kinematics. Annals of Biomedical Engineering. 2026. doi:10.1007/s10439-026-04051-7
BibTeX
@article{Tripathi2026,
author = {Tripathi, Anu and Wan, Yang and Zhu, Zhiren and Camci, Furkan and Turcsanyi, Sheila and Kachhadiya, Jeneel Pravin and Araiza Canizales, Mauricio and Brooks, Alison and Kesari, Haneesh and Andrews, Joseph and Snedden, Traci and Ferrazzano, Peter and Franck, Christian and Carlsen, Rika Wright},
title = {Field Evaluation of a Wearable Instrumented Headband Designed for Measuring Head Kinematics},
journal = {Annals of Biomedical Engineering},
year = {2026},
doi = {10.1007/s10439-026-04051-7}
}
EUVIMED