EUVIMEDEUVIMED entdecken
Crossref

Automatic Image Co-registration of Carotid Angiography and Intravascular Optical Coherence Tomography Based on Machine Learning Method: A Pilot Feasibility Study

Hui Xu, Jia-Nan Li, Yan Xu, Jun-Ren Ma, Kang Zong, Rui Zhu, Yi-Hui Cao, Peng-Fei Yang, Rui Zhao, Jian-Min Liu

Annals of Biomedical Engineering · 2026

DOI: 10.1007/s10439-025-03872-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2026. Verfasst von Hui Xu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Neurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Carotid Arteries, Machine Learning, Angiography. Die Arbeit nennt 32 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shenzhen Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study proposes a novel algorithm framework for optical coherence tomography (OCT) and carotid angiography co-registration (cACR), aiming to improve diagnostic precision and treatment planning for carotid artery disease. METHODS: The OCT-cACR algorithm integrates an enhanced U-Net segmentation model and a marker detection algorithm for segmenting target carotid vessels and detecting OCT probe markers. Based on the segmented target region, the You Only Look Once (YOLO) algorithm is further utilized to detect and track the OCT probe marker. The acquisition time point of each frame served as the matching parameter to achieve registration between the two modalities. Following registration, an expert compared the identified marker position on each angiography frame with its corresponding actual location to measure the resulting geographical error. The accuracy of cACR was validated using four real clinical cases, with a geographical error of less than 0.35 mm as the evaluation criterion. RESULTS: The segmentation model achieved higher accuracy (Dice coefficient: 0.867 ± 0.166) compared to baseline U-Net models. OCT-cACR demonstrated an accuracy of 93.33 to 100% in four test cases, thus achieving precise alignment of angiography and OCT images. CONCLUSION: The proposed cACR approach is feasible and accurate and may serve as a promising tool for improving the diagnosis and treatment of carotid artery diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceCarotid ArteriesMachine LearningAngiographyCarotid Artery DiseasesImage Processing, Computer-AssistedHumansPilot ProjectsFeasibility StudiesAlgorithmsMale

Stichwörter der Autor:innen

Angiography co-registrationArtificial intelligenceCarotid artery diseaseInterventional treatmentOptical coherence tomography

Autor:innen und Institutionen

  • Neurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China.
  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.
  • Shenzhen Vivolight Medical Device & Technology CO., Shanghai, China.
  • Neurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China. p.yang@vip.163.com.
  • Oriental Pan-Vascular Devices Innovation College, University of Shanghai for Science and Technology, Shanghai, China. p.yang@vip.163.com.
  • Key Laboratory of Molecular Neurobiology of Ministry of Education, Naval Medical University, Shanghai, China. p.yang@vip.163.com.

Förderung

  • National Natural Science Foundation of China
  • Shenzhen Research Foundation

Zitieren

APA

Xu, H., Li, J. N., Xu, Y., Ma, J. R., Zong, K., Zhu, R., Cao, Y. H., Yang, P. F., Zhao, R., & Liu, J. M. (2026). Automatic Image Co-registration of Carotid Angiography and Intravascular Optical Coherence Tomography Based on Machine Learning Method: A Pilot Feasibility Study. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-025-03872-2

Vancouver

Xu H, Li JN, Xu Y, Ma JR, Zong K, Zhu R, et al. Automatic Image Co-registration of Carotid Angiography and Intravascular Optical Coherence Tomography Based on Machine Learning Method: A Pilot Feasibility Study. Annals of Biomedical Engineering. 2026. doi:10.1007/s10439-025-03872-2

BibTeX
@article{Xu2026,
  author = {Xu, Hui and Li, Jia-Nan and Xu, Yan and Ma, Jun-Ren and Zong, Kang and Zhu, Rui and Cao, Yi-Hui and Yang, Peng-Fei and Zhao, Rui and Liu, Jian-Min},
  title = {Automatic Image Co-registration of Carotid Angiography and Intravascular Optical Coherence Tomography Based on Machine Learning Method: A Pilot Feasibility Study},
  journal = {Annals of Biomedical Engineering},
  year = {2026},
  doi = {10.1007/s10439-025-03872-2}
}