EUVIMEDEUVIMED entdecken
Crossref

Design of a Wearable Finger PPG-Based Blood Glucose Monitor

Mutian Wang, Xuelei Liu, Wenyi Han, Xinyu Lin, Xin Chen, Shun Zhao, Zhiqiang Zhuang, Leian Zhang, Peiqiang Su

Annals of Biomedical Engineering · 2025

DOI: 10.1007/s10439-025-03809-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2025. Verfasst von Mutian Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Shandong University of Technology, Zibo, 255000, Shandong, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Photoplethysmography, Blood Glucose, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Blood glucose monitoring is crucial for controlling diabetes. However, traditional fingertip pricking methods usually cause discomfort to patients and cannot achieve continuous monitoring. To overcome these limitations, we developed a novel, non-invasive, and wearable device for continuous blood glucose levels (BGLs) monitoring. METHODS: The device is equipped with a pulse oximeter, which has a visible wavelength (660 nm) and an infrared wavelength (880 nm) light-emitting diode (LED) to acquire finger photoplethysmography (PPG). The BGLs from PPG were estimated using a multi-layer perceptron (MLP) machine learning model, which was trained on dual-wavelength PPG intensity pertaining to various BGLs. We also analyzed the effect of MLP training parameters on the accuracy of blood glucose prediction. RESULTS: Experimental results indicate that 99.33% of the BGLs estimated from PPG lie in the clinically acceptable Clarke error grid (CEG) regions A and B, suggesting a high potential for accurate blood glucose monitoring with minimal clinical risk. Additionally, our 24-hour monitoring test further validates the device's capability to effectively track daily glucose fluctuations, which verifies its reliability in daily blood glucose monitoring. CONCLUSION: In conclusion, our novel wearable device for continuous blood glucose monitoring has shown feasibility and effectiveness. By leveraging PPG signals and a machine learning model, we have developed a promising alternative to traditional invasive blood glucose monitoring methods. This device has the potential to significantly improve the quality of life for diabetes patients by providing a more comfortable and continuous monitoring option.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesPhotoplethysmographyBlood GlucoseBlood Glucose Self-MonitoringFingersHumansMachine LearningMaleAdultEquipment DesignFemale

Stichwörter der Autor:innen

Continuous blood glucose monitoringFinger photoplethysmography (PPG)Machine learningMulti-layer perceptron (MLP)Wearable device

Substanzen

Blood Glucose

Autor:innen und Institutionen

  • School of Mechanical Engineering, Shandong University of Technology, Zibo, 255000, Shandong, China.
  • School of Mechanical Engineering, Shandong University of Technology, Zibo, 255000, Shandong, China. liuxl@sdut.edu.cn.
  • Shandong Huiyu Auto Parts Co., Ltd., Binzhou, 251702, Shandong, China. liuxl@sdut.edu.cn.
  • Shandong Huiyu Auto Parts Co., Ltd., Binzhou, 251702, Shandong, China.

Förderung

  • Natural Science Foundation of Shandong Province

Zitieren

APA

Wang, M., Liu, X., Han, W., Lin, X., Chen, X., Zhao, S., Zhuang, Z., Zhang, L., & Su, P. (2025). Design of a Wearable Finger PPG-Based Blood Glucose Monitor. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-025-03809-9

Vancouver

Wang M, Liu X, Han W, Lin X, Chen X, Zhao S, et al. Design of a Wearable Finger PPG-Based Blood Glucose Monitor. Annals of Biomedical Engineering. 2025. doi:10.1007/s10439-025-03809-9

BibTeX
@article{Wang2025,
  author = {Wang, Mutian and Liu, Xuelei and Han, Wenyi and Lin, Xinyu and Chen, Xin and Zhao, Shun and Zhuang, Zhiqiang and Zhang, Leian and Su, Peiqiang},
  title = {Design of a Wearable Finger PPG-Based Blood Glucose Monitor},
  journal = {Annals of Biomedical Engineering},
  year = {2025},
  doi = {10.1007/s10439-025-03809-9}
}
Kostenlos starten →