The Relation Between Hemiparetic Gait Patterns and Walking Function After Stroke, as Measured with Wearable Sensors
Annals of Biomedical Engineering · 2025
DOI: 10.1007/s10439-025-03754-7 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Annals of Biomedical Engineering, 2025. Verfasst von Brice Thomas Cleland und 2 weiteren Autor:innen. Beteiligte Einrichtung: Brain Plasticity Lab, Department of Physical Therapy, College of Applied Health Sciences, University of Illinois Chicago, 1919 W. Taylor St., Chicago…. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Stroke, Walking, Gait. Die Arbeit nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NICHD NIH HHS, National Center for Medical Rehabilitation Research.
Themen: Schlaganfall
Abstract (Originalsprache)
Purpose
After stroke, walking is characterized by hemiparetic patterns, quantified with force sensitive walkways and motion capture systems. Some joint-level kinematic patterns of walking also can be obtained with wearable sensors. The purpose of this project was to measure joint-level kinematic patterns during walking with wearable sensors and determine the association with walking speed and endurance in individuals with chronic stroke.
Methods
In this cross-sectional observational study, participants donned APDM Opal wearable sensors during walking tests (10-meter walk test or 6-min walk test). We extracted joint-level kinematic variables of elevation at midswing, circumduction, foot strike angle, and toe-off angle. Associations of each variable with walking speed and endurance were tested, and significantly associated variables were entered into a regression model.
Results
68 individuals with chronic stroke were included. We found that the less affected foot strike angle, less affected toe-off angle, and more affected toe-off angle were significant predictors of walking speed ( R 2 ≥ 0.71, p < 0.001). Less affected toe-off angle, more affected foot strike angle, and more affected toe-off angle were significant predictors of walking endurance ( R 2 ≥ 0.67, p < 0.001).
Conclusion
We found consistent evidence that greater toe-off angle (may reflect greater push-off) and lesser foot strike angle (may reflect lesser foot drop) were important predictors of greater walking speed and endurance. Our results suggest that wearable sensors can provide important information about joint-level kinematic patterns that are important for walking function. This information could help therapists target interventions toward specific deficits or compensatory patterns to improve walking.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Brain Plasticity Lab, Department of Physical Therapy, College of Applied Health Sciences, University of Illinois Chicago, 1919 W. Taylor St., Chicago, IL, 60612, USA.
- Brain Plasticity Lab, Department of Physical Therapy, College of Applied Health Sciences, University of Illinois Chicago, 1919 W. Taylor St., Chicago, IL, 60612, USA. smadhava@uic.edu.
Förderung
- NICHD NIH HHS
- National Center for Medical Rehabilitation Research
Zitieren
APA
Cleland, B. T., Kim, M., & Madhavan, S. (2025). The Relation Between Hemiparetic Gait Patterns and Walking Function After Stroke, as Measured with Wearable Sensors. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-025-03754-7
Vancouver
Cleland BT, Kim M, Madhavan S. The Relation Between Hemiparetic Gait Patterns and Walking Function After Stroke, as Measured with Wearable Sensors. Annals of Biomedical Engineering. 2025. doi:10.1007/s10439-025-03754-7
BibTeX
@article{Cleland2025,
author = {Cleland, Brice Thomas and Kim, Madeline and Madhavan, Sangeetha},
title = {The Relation Between Hemiparetic Gait Patterns and Walking Function After Stroke, as Measured with Wearable Sensors},
journal = {Annals of Biomedical Engineering},
year = {2025},
doi = {10.1007/s10439-025-03754-7}
}
EUVIMED