EUVIMEDEUVIMED entdecken
Crossref

Swin UNETR Segmentation with Automated Geometry Filtering for Biomechanical Modeling of Knee Joint Cartilage

Reza Kakavand, Peyman Tahghighi, Reza Ahmadi, W Brent Edwards, Amin Komeili

Annals of Biomedical Engineering · 2025

DOI: 10.1007/s10439-024-03675-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Biomedical Engineering, 2025. Verfasst von Reza Kakavand und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, CCIT216, 2500 University Drive NW, Calgary, AB, T2N 1N4,…. Hauptthemen laut MEDLINE: Cartilage, Articular, Knee Joint, Models, Biological. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 73 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Simulation studies, such as finite element (FE) modeling, offer insights into knee joint biomechanics, which may not be achieved through experimental methods without direct involvement of patients. While generic FE models have been used to predict tissue biomechanics, they overlook variations in population-specific geometry, loading, and material properties. In contrast, subject-specific models account for these factors, delivering enhanced predictive precision but requiring significant effort and time for development. METHODS: This study aimed to facilitate subject-specific knee joint FE modeling by integrating an automated cartilage segmentation algorithm using a 3D Swin UNETR. This algorithm provided initial segmentation of knee cartilage, followed by automated geometry filtering to refine surface roughness and continuity. In addition to the standard metrics of image segmentation performance, such as Dice similarity coefficient (DSC) and Hausdorff distance, the method's effectiveness was also assessed in FE simulation. Nine pairs of knee cartilage FE models, using manual and automated segmentation methods, were developed to compare the predicted stress and strain responses during gait. RESULTS: The automated segmentation achieved high Dice similarity coefficients of 89.4% for femoral and 85.1% for tibial cartilage, with a Hausdorff distance of 2.3 mm between the automated and manual segmentation. Mechanical results including maximum principal stress and strain, fluid pressure, fibril strain, and contact area showed no significant differences between the manual and automated FE models. CONCLUSION: These findings demonstrate the effectiveness of the proposed automated segmentation method in creating accurate knee joint FE models. The automated models developed in this study have been made publicly accessible to support biomechanical modeling and medical image segmentation studies ( https://data.mendeley.com/datasets/dc832g7j5m/1 ).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cartilage, ArticularKnee JointModels, BiologicalHumansFinite Element AnalysisBiomechanical PhenomenaMaleAdultAlgorithmsFemale

Stichwörter der Autor:innen

Cartilage segmentationFE modelingGeometry filteringSubject-specificSwin UNETR

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, CCIT216, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada.
  • McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada.
  • Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada.
  • Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, CCIT216, 2500 University Drive NW, Calgary, AB, T2N 1N4, Canada. amin.komeili@ucalgary.ca.
  • McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada. amin.komeili@ucalgary.ca.
  • Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, AB, T2N 1N4, Canada. amin.komeili@ucalgary.ca.

Förderung

  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Kakavand, R., Tahghighi, P., Ahmadi, R., Edwards, W. B., & Komeili, A. (2025). Swin UNETR Segmentation with Automated Geometry Filtering for Biomechanical Modeling of Knee Joint Cartilage. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-024-03675-x

Vancouver

Kakavand R, Tahghighi P, Ahmadi R, Edwards WB, Komeili A. Swin UNETR Segmentation with Automated Geometry Filtering for Biomechanical Modeling of Knee Joint Cartilage. Annals of Biomedical Engineering. 2025. doi:10.1007/s10439-024-03675-x

BibTeX
@article{Kakavand2025,
  author = {Kakavand, Reza and Tahghighi, Peyman and Ahmadi, Reza and Edwards, W Brent and Komeili, Amin},
  title = {Swin UNETR Segmentation with Automated Geometry Filtering for Biomechanical Modeling of Knee Joint Cartilage},
  journal = {Annals of Biomedical Engineering},
  year = {2025},
  doi = {10.1007/s10439-024-03675-x}
}
Kostenlos starten →